LG LCE3610SB Service Manual page 70

Ceramic glass radiant cooktop
Hide thumbs Also See for LCE3610SB:
Table of Contents

Advertisement

Components
Dual surface element
: Right Front(RF)
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
COMPONENT TEST
Test procedures
1. Refer to page 3-4 for the servicing procedure
2. Set the Multiple meter scale to the R x1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the (E1 & 1A)
and (E2 & 1A) the meter should indicate :
36.0 Ω ± 10%
- (E2 & 1A)
41.1 Ω ± 10%
- (E1 & 1A)
E1
1A
5. Touch the ohmmeter test leads to limiter
terminals 1A and 2A.the meter should indicate
continuity (0 Ω)
1A
2A
6. Touch the ohmmeter test leads to limiter
terminals 1B and 2B.
With the temperature below (150˚F/65.5˚C), the
meter should indicate an open circuit(infinite).
With the temperature above (150˚F/65.5˚C), the
meter should indicate continuity (0 Ω).
1B
2B
E2
- 70 -
Results
Normal: Approximately 36 Ω
Normal: Approximately 41.1 Ω
Normal: continuity
(below 0.5 Ω)
If not replace
<Normal>
Below (150˚F/65.5˚C)
open circuit (infinite).
Above (150˚F/65.5˚C)
continuity (0 Ω)
If not replace
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents