Insulator & Harness
WARNING
• DISCONNET power supply before servicing.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal injury, death
or electrical shock.
1. Attach harness using the 5 holders and the back side of the insulator.
2. Turn over bracket and pull connectors though each corresponding hole.
Black, Blue, Brown, red, red
Brown, Pink, Red, Red
3. Check the terminals and wire colors.
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
ASSEMBLY
• Be careful when you work on the Cooktop
handling the sheet metal part.
- 48 -
CAUTION
LGE Internal Use Only