Ordering Information; Specifications - Omron E4PA-N Manual

Ultrasonic displacement sensor
Table of Contents

Advertisement

Ordering Information

■ Sensors
(Refer to Dimensions on page 7.)
Sensing range
50 to 500 mm
120 to 2,000 mm
240 to 4,000 mm
400 to 6,000 mm
■ Accessories (Order Separately)
Sensor I/O Connectors
A Connector is not provided with the Sensor. Be sure to order a Connector separately. (Refer to Dimensions on page 8.)
Cable
Standard Cable
4-to-5 Conductor Conver-
sion Cable (See note.)
Note:
When you use a 4-pole sensor connector cable, the E4PA-C01 is useful for converting from 4 to 5 poles. If this is done, however, you
cannot use the mutual interference prevention function.
Setting Plug
A plug is not provided with the Sensor. (Refer to Dimensions on page 8.)
Shape

Specifications

■ Ratings/Characteristics
Item
Sensing range
Dead band distance
Standard sensing object
Applied frequency
Response time
Power supply voltage
Power consumption
Analog output
Protective circuit
Mutual interference prevention cycle time 10 ms
Linearity
Repeat accuracy (See note.)
Temperature influence
Voltage influence
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Connection method
Degree of protection
Weight (packed)
Materials
Accessories
Note:
Values are given one hour after power-up. The outputs may fluctuate due to external disturbances.
E4PA-N
2
Arrow.com.
Arrow.com.
Downloaded from
Downloaded from
Model
E4PA-LS50-M1-N
E4PA-LS200-M1-N
E4PA-LS400-M1-N
E4PA-LS600-M1-N
Shape
2 m
Straight
5 m
0.3 m
Model
Remarks
E4PA-P1
Attached to
each Sensor
E4PA-LS50-M1-N
50 to 500 mm
0 to 50 mm
100 × 100 mm flat plate
Approx. 380 kHz
63 ms max.
10 to 30 VDC; ripple (p-p): 10% max.
1,800 mW max.
Current output: 4 to 20 mA (Allowable load resistance: 500 Ω max.)
Voltage output: 0 to 10 V (1,000 Ω min.)
Load short-circuit protection, mutual interference prevention
±1% FS max.
0.1% FS max.
±1% FS of output value at +23°C in the temperature range of -10 to 55°C
±5% FS max. within rated power supply voltage range
Operating: -10 to 55°C (with no icing or condensation)
Storage:
-40 to 85°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC (50/60 Hz) for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1-mm double amplitude for 2 hours each in X, Y, and Z directions
2
Destruction: 300 m/s
three times each in X, Y, and Z directions
5-conductor connector
IEC60529: IP65
Approx. 240 g
Case:
Stainless steel (SUS303)
Sensing surface:
PBT resin, polyurethane, glass epoxy resin
Clamping nut:
Stainless steel (SUS303)
Operation Manual
Ultrasonic Displacement Sensor
Cable length
5 conductors
---
E4PA-LS200-M1-N
120 to 2,000 mm
240 to 4,000 mm
0 to 120 mm
0 to 240 mm
Approx. 180 kHz
Approx. 85 kHz
195 ms max.
440 ms max.
34 ms
77 ms
Approx. 320 g
Model
XS2F-D521-DG0-A
XS2F-D521-GG0-A
E4PA-C01
E4PA-LS400-M1-N
E4PA-LS600-M1-N
400 to 6,000 mm
0 to 400 mm
Approx. 65 kHz
850 ms max.
143 ms
Approx. 400 g

Advertisement

Table of Contents
loading