9.1.2
Test Connections and
Test Values
The plug and socket connections
of wires 1 to 4 must be disconnected
to test the individual components.
Com-
Ohmmeter connection
ponent
(use either test lead)
Lead 1
Switch
Switch
1)
terminal
Heating
Connector
element
on wire 3
in rear
handle
Heating
Connector
element
on wire 2
in front
handle
Generator
Connector
on wire 1
1)
Remove wire for this purpose
Resistance
Lead 2
Spec.
Actual
(reading)
Ground
0
-
Connector
0,25
approx. 0,25 Heating element OK
on wire 4
-
0
Ground
1,6
approx. 1,6
-
0
Ground
0.6
approx. 0.6
-
0
If faulty
Cause
Remedy
Switch faulty
Replace
switch
Break in wire, heating
Replace
element damaged
heating element
Short circuit -
Repair
damaged insulation
insulation
Heating element OK
Break in wire, heating
Replace
element damaged
front handle
Short circuit -
Repair
damaged insulation
insulation
Generator OK
Break in wire,
Replace
generator damaged
generator
Short circuit -
Repair
damaged insulation
insulation
66