INSTALLATION
Indoor Unit Connections
Using a Conduit for Indoor Unit Wiring / Cable Installation
1. Indoor unit includes a conduit bracket that can be found in the accessory kit. Assemble the conduit and
bracket with a grommet and washer (field-supplied or included with the elbow connector).
2. Guide communication / connection (power) cable insulation into the conduit.
3. Attach the conduit / bracket assembly to the indoor unit using the screws found in the accessory kit.
4. To protect the piping, condensate drain, and conduit from the elements, add a lineset cover from the indoor access hole to the outdoor
unit.
Bundling
If a conduit or piping set cover is not used on the connection from the outdoor unit to the
interior, bundle both separately insulated refrigerant pipes, the drain hose, and outdoor
unit to indoor unit communication / connection (power) cable together with wide vinyl
tape.
1. Both piping must be fully and separately encased in insulation material: Overlap the
field installation piping insulation material and the indoor unit piping insulation mate-
rial.
2. Bind together the two pipes, using vinyl tape. Make sure there are no gaps during the
binding. Verify that any insulation material cutting lines are placed upward.
3. Bind together the two pipes, using narrow vinyl tape. Make sure there are no gaps
during the binding.
4. Continue to wrap the indoor unit pipe as connected to the outdoor connection pipe.
5. Using a wider vinyl tape, bundle the piping and drain hose together.
• Tape must be sufficient to cover the piping in order to fit into the rear piping housing
area at the back of the indoor units.
22
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
MULTI
MULTI
Figure 18: Liquidtight 3/4 Inch
Elbow Connector Attached to
Flexible Conduit.
Figure 19: Bundling the Connection Components
(From Outdoor Unit to Indoor Unit).
Connection pipe
Vinyl tape (wide)
Wrap with vinyl tape
Connecting cable
Vinyl tape (narrow)
Figure 20: Cut Line Position.
Cut Line at Top
Figure 21: Cutaway of Proper Pipe and Cable
Bundling.
Tape
Connection
Cable
Drain Hose
Piping
F
F
MAX
-
Indoor unit pipe
Pipe