TROUBLESHOOTING (cont.)
Screen Displayed
NO FUNNEL
PRESENT
TEMPERATURE
TOO LOW
CHECK FUNNEL
FOR FRESH COFFEE
PRESS BREW
TO BREW ANYWAY
BREW STOPPED!
FUNNEL REMOVED?
TO FINISH:
PRESS BREW
TO CANCEL
PRESS ON/OFF
Possible Cause
1. SMART FUNNEL not fully inserted
into the funnel rails.
2. Not using a SMART FUNNEL,
and the FUNNEL DETECT function
is activated (on).
1. Water temperature in the tank
does not meet the SET READY
TEMPERATURE.
1. Brew funnel was not removed
after the previous brew cycle was
finished.
1. Brew funnel was moved out of
position after the brew cycle was
started.
Page 40
Troubleshooting Procedure
Position the funnel so that the sensor
is directly beneath the sensor coil on
the brewer.
Disable the FUNNEL DETECT func-
tion.
(a) Wait for the brewer to heat to the
proper temperature.
(b) Disable the BREW LOCKOUT
function.
Remove funnel, check contents, and
insert back into the funnel rails.
OR
Press BREW to start a brew cycle
without removing the funnel.
To resume brewing, correctly posi-
tion the funnel and press BREW
again. The brew cycle will resume
from the point it was interrupted.
OR
Press ON/OFF to terminate the
cycle.
34025.2 071105