Bunn SINGLE SH DBC Programming Manual

Bunn SINGLE SH DBC Programming Manual

Hide thumbs Also See for SINGLE SH DBC:

Advertisement

SINGLE
W/SMART FUNNEL
S/N SNG0033000 & UP
PROGRAMMING MANUAL
41341.0000C 4/12 ©2008 Bunn-O-Matic Corporation
SH DBC
®
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
DUAL
W/SMART FUNNEL
®
®
SH DBC
®
S/N DUAL068000 & UP
E R
N
I O
N T
U T
C A
D E
C A
R D
C A
D IS
!
IF :
E D
C K
E D
P T
Y
R A
C H
A T
Y
E M
E
. C
D R
N
A M
C R
H E
F L
IC
. S
E D
T R
O IL
D W
H
E C
T E
H IG
E L
. B
E A
O N
D
. H
D
S E
S E
P O
. U
E X
T S
R
E N
R Y
. O
E M
J U
T S
E L
IN
IO
N
AT
E N
K S
O R
N T
R P
R IS
C O
C O
L Y
IC
O T
M P
AT
E L
-M
N N
E H
C O
N N
-O
B U
F U
A R
T O
85
19
R E
IL U
F A
8
: 65
P N
®
®

Advertisement

Table of Contents
loading

Summary of Contents for Bunn SINGLE SH DBC

  • Page 1 S/N SNG0033000 & UP D IS IF : O IL H IG R IS IL U : 65 PROGRAMMING MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 41341.0000C 4/12 ©2008 Bunn-O-Matic Corporation...
  • Page 2 AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
  • Page 3: Table Of Contents

    INTRODUCTION The brewer incorporates a wireless interface system that allows the DBC Grinder to load certain information into the "programming tag" located inside the handle of the funnel. This information includes what flavor of coffee is being ground and what batch size will be brewed (small, medium, or large). Once the correct flavor name and amount of coffee is ground, the funnel is loaded into the brewer.
  • Page 4 GLOSSARY AD CARD: An assembly consisting of a computer chip and an instruction label. Used for loading advertising messages into the brewer. BREW LOCKOUT: The inability to initiate a brew if the water temperature is less than the ready temperature programmed into the brewer.
  • Page 5: Programming

    This is used to access the programming mode and is also used to scroll forward through the function list. 2. Upper left corner of the "B" in the BUNN logo This is used to scroll backwards through the function list.
  • Page 6: Programming The Brewer

    PROGRAMMING THE BREWER The programming of the brewer is divided into two levels. There is one function in Level 1. All other functions are accessed in Level 2. The following function screens are in order of appearance. Each screen will have instructions on how to access, and the procedures to program the various functions of the brewer.
  • Page 7: Recipe Programing Methods

    SETTINGS FOR DUAL REFER TO NAME LIST BREWERS GO TO REVIEW RECIPES IN GRINDER MANUAL AND FOLLOW INSTRUCTIONS CONTACT BUNN-O-MATIC TO VIEW A LIST OF EXISTING RECIPES, FOR ASSISTANCE GO TO REVIEW RECIPES AND FOLLOW THE INSTRUCTIONS P2369-1 Page 7...
  • Page 8: Flow Diagram

    PROGRAMMING THE BREWER (cont.) PROGRAM FLOW DIAGRAM LEVEL 1 Press upper right hidden switch for approximately 2 seconds, until the following screen appears. BREW LOCKOUT? DONE Returns to normal operating mode LEVEL 2 Press upper right hidden switch for approximately 4 seconds, until “UNITS” appears on screen. Sets unit of Sets unit of UNITS...
  • Page 9 PROGRAMMING THE BREWER (cont.) PROGRAM FLOW DIAGRAM (Cont.) TRANSFER COMPLETE SET ALL FULL BYPASS 3 BATCHES DONE (both sides ENABLE ADS? for DUAL DONE brewers) SELECT METHOD EASY NEXT MANUAL 3 BATCHES DONE? MANUAL SET TEMP: 200°F DONE EASY SET ALL FULL SET PULSE BREW 3 BATCHES...
  • Page 10 PROGRAMMING THE BREWER (cont.) PROGRAM FLOW DIAGRAM (Cont.) CONTAINER RDY? LEFT BREW VALVE NEXT QUIT L BYPS OZ/M XX.X SPRAY HEAD CAL? DONE LEFT BYPASS CALIBRATE SPRAY NEXT PRESS BREW START DUAL R BYPS OZ/M XX.X BYPASS CAL? BREWERS DONE LEFT FUNNEL LOCK SINGLE NEXT...
  • Page 11 PROGRAMMING THE BREWER (cont.) UNITS (SETTING UNITS OF MEASURE) 2. Press DONE to proceed. The display should now This function allows the units of measure to be read CHANGING UNITS!! WILL ERASE!! ... ALL set in English or Metric readings for all screens. The PREVIOUSLY STORED RECIPES AND ALL SETUP program is defaulted to English.
  • Page 12: Enable Energy Saver

    PROGRAMMING THE BREWER (cont.) ENABLE ENERGYSAVR This function allows the operator to enable the ENERGY SAVINGS mode function and set the idle time. Once 10. Once the idle time has expired, the display will the set idle time has expired, the operator can choose read either ENERGY SAVER...NO TEMPERATURE to have the heaters either turn off, or reduce the tank or ENERGY SAVER...REDUCED TEMPERATURE,...
  • Page 13: Set New Recipe (Using A Smart Funnel And G9-2T Dbc Or Mhg Grinder)

    PROGRAMMING THE BREWER (cont.) SET NEW RECIPE Procedure for Setting the Recipe: Using a Smart Funnel and a G9-2T DBC or MHG NOTE: Before beginning setup, place a server beneath Grinder: the brew funnel (left side on DUAL brewers). This function allows the operator to set BREW 1.
  • Page 14: Set Pulse Brew Times

    PROGRAMMING THE BREWER (cont.) SET NEW RECIPE (cont.) PULSE BREW - MANUAL METHOD. SET DRIP 8. Using (-) and (+), set the amount of brew water, in TIME. (Refer to SET DRIP TIME for description). ounces, to be dispensed for that particular batch size.
  • Page 15: Set New Recipe (Using A Recipe Card)

    BYPASS PERCENTAGES, PULSE BREW TIMES, and DRIP-OUT TIMES for that particular coffee NAME. These can all be loaded in seconds. CARD CONTAINS Contact Bunn-O-Matic Corporation for the avail- RECIPE FOR ability of RECIPE CARDS. NOTE: Instructions to program the brewer and grinder...
  • Page 16: Set New Recipe (No Smart Funnel Nor G9-2T Dbc Or Mhg Grinder)

    This includes BREW MODIFY SHOW NEXT VOLUMES, BYPASS PERCENTAGES, PULSE BREW TIMES, and DRIP-OUT TIMES. The brewer will perform in the same capacity as a standard Bunn Single/Dual Brewer. The instructions for programming the NO NAME BREW OZ. XX.X settings are on the following pages.
  • Page 17: Review Recipes/Modify Recipes/Set Up No Name Coffee

    PROGRAMMING THE BREWER (cont.) REVIEW RECIPES/MODIFY RECIPES/SET UP NO NAME COFFEE FAVORS: This function has three parts. It allows the operator 3. Press and release SHOW. The screen will scroll to view the brew settings for the various coffee names through all the brew settings for that particular programmed into the brewer.
  • Page 18 PROGRAMMING THE BREWER (cont.) 4. Press and release MODIFY. The display should BREW OZ (SETTING OR ADJUSTING BREW VOL- read BREW OZ: and a batch light will be blinking. UMES) This function allows adjustment of the brew vol- Press and release the batch size to be modified. umes for each batch.
  • Page 19 PROGRAMMING THE BREWER (cont.) % BYPASS coffee name to be modified. This function allows adjustment of the amount of 4. Press and release MODIFY. The display should water that bypasses the grounds. The number signi- read BREW OZ. fies the percentage of the brew volume which does 5.
  • Page 20: Set Pulse Brew

    PROGRAMMING THE BREWER (cont.) SET PULSE BREW: Modifying pulse brew: This function allows the operator to program Range: 1st on time - off to 4 minutes the brewer to "pulse” the sprayhead flow on and off Off time - off to 4 minutes during a brew cycle (start and stop the flow of water Last on time - Preinfusion to 4 minutes out of the sprayhead).
  • Page 21: Easy Method

    PROGRAMMING THE BREWER (cont.) SET PULSE BREW (cont.) REVIEW RECIPES? EXIT TO NEXT FUNCTION SINGLE DUAL SCREEN BREWERS BREWERS NO-NAME NO-NAME LEFT MODIFY SHOW NEXT MODIFY SHOW NEXT SCREEN DISPLAYED PRESS ADVANCES TO ALL OTHER BREW OZ: XX.XX DONE COFFEE NAMES PROGRAMMED 3 BATCHES DONE? IN THE BREWER"S MEMORY % BYPASS XX.X...
  • Page 22 PROGRAMMING THE BREWER (cont.) SET PULSE BREW - EASY METHOD SET PULSE BREW? NOTE: The procedure to enter the PULSE BREW function must be performed prior to following the steps listed below. SELECT METHOD 1. The display should read BREW TIME: X.XX and EASY NEXT MANUAL a batch size indicator will be flashing.
  • Page 23 PROGRAMMING THE BREWER (cont.) SET PULSE BREW - MANUAL METHOD SET PULSE BREW? NOTE: The procedure to enter the PULSE BREW function must be performed prior to following the steps listed below. SELECT METHOD EASY NEXT MANUAL 1. The display should read 1st ON TIME X:XX and a batch size indicator will be flashing.
  • Page 24 PROGRAMMING THE BREWER (cont.) 11. When finished, press another batch size and repeat DRIP TIME (now displayed on "non" funnel lock step 10 until all three sizes are set. units as well) 12. When finished, press DONE. The display should This function allows the setting or modification read 3 BATCHES DONE? of the funnel locks to stay engaged after the end of a...
  • Page 25: Assign Recipes

    PROGRAMMING THE BREWER (cont.) COPY SETTINGS (NO NAME COFFEE SETTINGS ASSIGN RECIPES ONLY) This function is used on DUAL brewers only to This function allows for assigning a coffee name transfer all the brew settings from a NO NAME coffee other than NO-NAME to the BREW switch.
  • Page 26: Enable Ads

    PROGRAMMING THE BREWER (cont.) 4. When finished, press and release DONE to save COPY SETTINGS (NO NAME COFFEE SETTINGS ONLY) the new setting, exit the ENABLE ADS function and (cont.) advance to the next function screen, SET TEMP. Another alternative is to press and release the 2.
  • Page 27: Set Ready (Ready Temperature)

    PROGRAMMING THE BREWER (cont.) SET TEMP (cont.) REFILL - Range: 20 to 230 This function allows the operator to adjust the 2. To adjust the brew temperature, press (-) to de- sensitivity of the refill circuit. This is mainly a trouble- crease or (+) to increase the brew temperature.
  • Page 28 PROGRAMMING THE BREWER (cont.) SPRAY OZ/M (SINGLE BREWERS) SPRAY OZ/M (DUAL BREWERS) This function allows the operator to view or to enter This function allows the operator to view or to enter the actual flow rate coming out of the sprayhead. This the actual flow rate coming out of the sprayhead.
  • Page 29 PROGRAMMING THE BREWER (cont.) BYPASS OZ/M (DUAL BREWERS) BYPASS OZ/M (SINGLE BREWERS) This function allows the operator to view or to enter This function allows the operator to view or to enter the actual flow rate coming out of the bypass nozzle. the actual flow rate coming out of the bypass nozzle.
  • Page 30: Calibrate Flow

    PROGRAMMING THE BREWER (cont.) CALIBRATE FLOW brewers) located on the front switch panel to exit the CALIBRATE FLOW function and return to the This function allows the operator to enter the actual MAIN SCREEN. flow rate of the sprayhead and the bypass (for each side on DUAL brewers) by dispensing both separately for one minute.
  • Page 31 PROGRAMMING THE BREWER (cont.) CALIBRATE FLOW? Procedures to calibrate the bypass flow rate: 1. Place a container, accurately graduated in ounces, EXIT TO NEXT FUNCTION and with a minimum capacity of 60 ounces, below SCREEN the funnel on the brewer to be calibrated. 2.
  • Page 32: Brew Counters (View/Reset)

    PROGRAMMING THE BREWER (cont.) BREW COUNTERS 3. To advance to the other counters, press and release This function allows the operator to track the NEXT. The four counters for DUAL brewers are as number of brew cycles completed. The number of follows: brew cycles on the left side, the right side, and the total LEFT - total brews on left side (resettable)
  • Page 33 PROGRAMMING THE BREWER (cont.) FUNNEL DETECT (optional) SERVER DETECT This function allows the operator to prevent the start This function allows the operator to prevent the of a brew cycle if a Soft Heat server is not positioned start of a brew cycle if a Smart Funnel is not positioned correctly on the brewer.
  • Page 34: Service Tools

    PROGRAMMING THE BREWER (cont.) SERVICE TOOLS 5. The display should read TEST OUTPUTS. This function allows the testing of individual com- 6. Press and release YES. The display should read: ponents and the ability to check switches for proper BREW VALVE on SINGLE brewers function.
  • Page 35: Test Outputs (Components)

    PROGRAMMING THE BREWER (cont.) SERVICE TOOLS (cont.) SERVICE TOOLS? EXIT TO NEXT FUNCTION SCREEN TEST OUTPUTS? SINGLE DUAL BREWERS BREWERS TEST SWITCHES? PRESS AND RELEASE ® SYMBO L BREW VALVE LEFT BREW VALVE NEXT NEXT NOTHING PRESSED BYPASS LEFT BYPASS NEXT NEXT SINGLE...
  • Page 36 PROGRAMMING THE BREWER (cont.) SERVICE TOOLS (cont.) lease the right hidden switch (®). This will return NOTE: The tank heater will automatically turn off if to TEST SWITCHES?. Press and release switch left on too long. again to advance to TEST SERVERS?. Another alternative is to press and release the ON/OFF 26.
  • Page 37: Factory Defaults (Reset)

    PROGRAMMING THE BREWER (cont.) SERVICE TOOLS (cont.) 3. Press and hold the upper right hidden switch until TINGS. This screen will alternate with ARE YOU the display reads UNITS. Release the switch. SURE?. Continue pressing and releasing the upper right 4.

Table of Contents