POWER UNIT INSTALLATION

Refer to page 4 for information on locating the power unit.

MOUNTING

This section refers to Figures 51 and 52.
CAUTION
On vacuum models VX475, VX550 and VX1000,
DO NOT REMOVE either of the BOTTOM red cap
plugs. Removing these glued plugs will damage
the unit. Only remove and use the outlets covered
by the green TOP plugs. For VX475C, VX550C and
VX1000C models, DO NOT REMOVE either of the
TOP red cap plugs that are glued to the unit.
Removing these glued plugs will damage the unit.
Only remove and use the outlets covered by the
green BOTTOM plugs.
Your power unit mounts to the wall using a mounting system.
The wall mounting bracket, provided with your power unit,
mounts to the wall. It has 4 fingers at the top and 4 others at
the bottom. The power unit has 4 upper openings and 4
lower openings which are designed to slide onto the fingers
of the wall mounting bracket. Be sure to follow the
instructions below for proper installation.
1. Locate power unit within six feet (1.82 m) of a grounded
electrical outlet. NuTone's models VX475 and VX550
Series require a 120V, individual 20-amp branch circuit
with a NEMA 5-20R receptacle. VX1000 Series require a
240 VAC, individual 20-amp branch circuit with a NEMA
6-20R receptacle.
CAUTION
Make sure to fix the wall mounting bracket with the
screws directly onto a stud for a solid installation.
2. Refer to Figure 27 to maintain minimum wall clearance
dimensions.
3. Position and install the wall mounting bracket with the
provided screws. Refer to Figure 52 for proper mounting
dimensions.
4. Using the mounting screws provided, fix the mounting
bracket on the wall through two upper and two lower
mounting holes.
5. Prior to installing the power unit onto the wall, you must
do the wiring, see page 33 for more details.
6. Hang power unit onto wall mounting bracket. Make sure
both upper and lower mounting openings on the back of
the power unit are engaged with corresponding wall
bracket fingers. Pull down the power unit to secure.
7. Open the door on the front side of the power unit. For
VX475, VX550 & VX1000 models, make sure bag is
installed properly on bag holder and holder is locked in
upright position. For models VX475C, VX550C &
VX1000C, make sure the cyclonic filter media is properly
seated. See Homeowners Guide if necessary. Close the
door.
Do not install outdoors.
MINIMUM WALL CLEARANCES
24"
(610 mm)
VX550 & VX1000 Series:
24"
(610 mm) MINIMUM TO CEILING
UTILITY
VALVE
18"
MINIMUM ABOVE FLOOR
(457 mm)
30 3/8"
MOUNTING
HOLES
MOUNTING
1" TYP.
HOLES
31
WARNING
!
24"
(610 mm)
11" (279 mm)
VX475 Series:
13,75" (349 mm)
FRONT VIEW
FIGURE 51
30 3/8"
¾" TYP.
12 5/8"
43 7/16"
MIN.
DIMENSION
30 ¾"
30 ¼"
FIGURE 52