ORIGINAL VACPAN
INSTALLATION INSTRUCTIONS
NOTE: Please read instructions prior to installation.
INSTALLATION TIPS
Plan the location of your ORIGINAL VACPAN to be
conveniently located for sweeping clean-ups.
Also consider ease of access of vacuum tube piping
connections during installation.
The leading edge of the ORIGINAL VACPAN must sit
flush with the finished floor.
For maximum clearance, use part# CV382S universal
short 90˚ elbow for connection to VACPAN.
Do not glue the connection between ORIGINAL
VACPAN and elbow to allow for future removal.
Prior to final installation, check for an airtight seal
between ORIGINAL VACPAN and elbow. Teflon tape may
be used if required.
Allow for 1/2" vertical play in vacuum tube piping
at ORIGINAL VACPAN location, so that final piping
connections can be made.
UNDER CABINET INSTALLATIONS
Refer to Figure 46.
ORIGINAL VACPAN requires a minimum 2 ¼" toe kick
height.
Once the ORIGINAL VACPAN location is determined,
cut a 6 ¾" long x 1 ¾" high slot in the cabinet toe kick
to accept the ORIGINAL VACPAN.
FIGURE 46
AH0001A
UNDER CABINET INSTALLATIONS
QUICK TRIM
CV382S
COVER PLATE
UNIVERSAL
ORIGINAL
SHORT 90° ELBOW
VACPAN™
CABINET FLOOR
SUB FLOOR
Run vacuum tube piping and low voltage wire from the
main piping line to the ORIGINAL VACPAN location.
Access for final piping connections must be made.
Access From Below
If access is available from below, cut an access hole
through the subfloor underneath the cabinet, positioned
so that final piping connections can be made by
reaching through the access hole.
Access Through Cabinet Floor
Access can be made through the finished cabinet floor.
Cut a 2 ¾" x 3 ½" access hole, positioned so that final
piping connections can be made by reaching through the
access hole. CI366 Trim Plate can be used to cover the
hole after installation.
Access Through Cabinet Toe Kick
Access can be made through the cabinet toe kick by
cutting up to 10 ½" x 4" slot and using the ORIGINAL
VACPAN Quick Trim Cover Plate (CI366 Trim Plate sold
separately). If required, score back of Quick Trim Cover
Plate with a knife and snap along grooves for height
adjustment.
Attach low voltage wires to ORIGINAL VACPAN
terminal connections marked "low voltage only".
Slide ORIGINAL VACPAN into mounting slot and secure
to toe kick using two #6 screws provided.
Reach through access hole and make final piping
connections.
CI366
TRIM PLATE
ROUGH-IN
OPTIONS
SUB FLOOR