Chapter 3 Test Equipment, Service Aids And Tools; Recommendedtest Equipment; Table 3-1. Recommended Test Equipment - Motorola MCS 2000 Service Instructions Manual

Hide thumbs Also See for MCS 2000:
Table of Contents

Advertisement

Chapter 3 Test Equipment, Service Aids and Tools

RecommendedTest Equipment

The list of equipment contained in the table below includes all of the standard test equipment
required for servicing two-way mobile radios, as well as several unique items designed specifically
for servicing the radio. Battery-operated test equipment is recommended when available. The
"Characteristics" column is included so that equivalent equipment may be substituted; however,
when no information is provided in this column, the specific Motorola model listed is either a unique
item or no substitution is recommended.
Motorola
Model Number
R2000 Series
R1150C*
S1053D*
HM-203-7*
SKN6008A*
SKN6001A*
S1350C*
ST1213B (VHF)*
(Superseded by
ST1217B)
ST1217B (VHF)*
ST1223B (UHF)*
(Superseded by
ST1237B and ST1227B)
ST1237B (UHF R1)*
ST1227B (UHF R2)*
T1013A
(Supersedes R1065A)
R1065A
(Superseded by T1013A)
S1339A
R1013A*
R1011B
(Supersedes S1347D &
S1348D)
S1347D or
S1348D (programmable)
(Superseded by R1011B)
* Any of the R2000 Series system analyzers will substitute for items with an asterisk (*).

Table 3-1. Recommended Test Equipment

Description
System Analyzer
This monitor will substitute
for items with an asterisk (*)
Code Synthesizer
220 VAC Voltmeter
1mV to 300V, 10-Mohm input
100 VAC Voltmeter
impedance
Power Cable for Meter
Test Leads for Meter
Watt Meter
50 ohm, ±5% accuracy
Plug-in Element
10 Watts, maximum
0-1000 MHz, 300W
Plug-in Element
RF Dummy Load
Plug-in Element
Plug-in Element
Load Resistor
0-1000MHz, 300W
Load Resistor
10-watt Broadband
RF Millivolt Meter
100µV to 3V rf
10kHz to 1.2 GHz
SINAD Meter
DC Power Supply
0-40Vdc, 0-30 Amps
DC Power Supply
0-20Vdc, 0-5 Amps
Characteristics
Frequency/deviation meter and sig-
nal generator for wide-range trouble-
shooting and alignment.
Injection of audio and digital signal-
ling codes.
Audio voltage measurements.
Transmitter power output measure-
ments.
For use with Wattmeter.
For use with Wattmeter.
RF level measurements.
Receiver sensitivity measurement.
Current limited bench power supply.
Current limited bench power supply.
Application

Hide quick links:

Advertisement

Table of Contents
loading