Dimensions & Configuration - Rinnai RSEP1S25P Installation And Operation Manual

Super high-efficency (se+) series infrared gas heater
Table of Contents

Advertisement

14. HEATER DIMENSIONS & CONFIGURATIONS
Table 5: CAPACITIES & CONFIGURATIONS
MODEL
RSEP1S25X (NG and LP)
RSEP1S35X (NG and LP)
RSEP2S50N (NG)
* For a multiple heater installation, the first heater is sized at 40VA and each consecutive
heater is sized at 20VA. The sum total will be the required Transformer size. If total VA
exceeds one transformer size select the next higher VA rated transformer.
Figure 5: DIMENSIONS
Front View
15. MOUNTING KIT OPTIONS (NOTE: For unusual mounting application contact
Optional mounting kits available:
ITEM NO
1
2
3
4
WARNING: This heater must be rigidly mounted to prevent movement from wind force.
Mounting Brackets: Ensure that anchoring to the structure is of sufficient
strength, integrity and workmanship, to adequately support the weight of the
heater and any other potential loads such as snow build up, and wind force.
SE+ Series Infrared Gas Heater Installation and Operation Manual
Voltage
VAC
24
A
PART NUMBER
903000009
903000022
903000028
903000026
Current
Btu/hr input
amps
23,000
23,000
35,000
40 VA*
35,000
50,000/35,000
Rinnai.)
DESCRIPTION
CEILING MOUNT BRACKET
WALL MOUNT BRACKET
ARM MOUNT BRACKET
POST BRACKET
20
Total
Weight (lbs).
32
32
44
44
49
End View
10"
13"
Length
< A >
30 1/2"
30 1/2"
43 1/2"
43 1/2"
48 1/4"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rsep1s25nRsep1s35pRsep1s35nRsep2s50n

Table of Contents