2 Prerequisites and Dependencies
Figure 2-1
Figure 2-2
In brake logic, p1275.5 (Brake with feedback) should be set to "No". The brake
checkback should be evaluated using the Brake Feedback function of the
ExtendedCraneDCC.
Figure 2-3
In brake logic, p1216 (Motor holding brake opening time) should be set to 0 which
avoids the delay in the operation enabled status word of the sequence control.
Instead, brake release time should be configured in p21902 (BrakeFeedback_
BrakeReleaseTime (ms)). Also, p1217 (Motor holding brake closing time) should
be set to 0 and instead, brake closing time should be configured in p21908
(BrakeFeedback_BrakeCloseTime (ms)).
Figure 2-4
In brake logic, the below settings are necessary in "Close brake" logic.
Extended Crane Drive-Based Technology AC
Extended Crane Drive-Based Technology SINAMICS S120
DCC Add-On Description 109767457,
p1215 (Motor holding brake configuration) = [1]
p1215 (Motor holding brake configuration) = [3]
p1275.5 (Brake with feedback) = "No"
p1216 = 0 ms & p1217 = 0 ms