Siemens SINAMICS S120 Manual page 45

Drive-based technology dcc addon description
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

3 DCC Blocks
SINAMICS
parameter
number
p22288
H2_ResetTorque
p22289
H2_rTorqueBuildingSpeed
SetpointLimit (%)
p22290
H2_rTorqueBuildingSpeed
SetpointRamptime (%)
r22310
H2_boOut_SP_EnableBrake
StoreValue (p22070)
r22311
H2_rOut_SP_TorqueValue
Retain (p22071)
r22312
H2_boOut_SP_Command
OpenBrake (p22072)
r22313
H2_boOut_SP_Command
CloseBrake (p22073)
r22314
H2_rOut_ActualTorque (%)
r22315
H2_rOut_SpeedControllerI-
ComponentAtPreviousBraking (%)
r22316
H2_rOut_ActualTorqueAtPrevious
Braking (%)
r22317
H2_rOut_TorqueToBeProven (%)
Extended Crane Drive-Based Technology AC
Extended Crane Drive-Based Technology SINAMICS S120
DCC Add-On Description 109767457,
Name
Connection
V1.2,
09/2019
Default
type
assignment
IN
0
IN
1
IN
5000
OUT
0
OUT
0
OUT
0
OUT
0
OUT
0
OUT
0
OUT
0
OUT
0
Data
Meaning
type
monitoring fault will
be triggered.
BOOL
Parameter only used
during
commissioning,
deletes last saved
braking torque.
REAL
Additional speed
setpoint injected to
build torque while
brake is closed for
hoist 2
Time period over
REAL
which p22289
(H2_Torque
BuildingSpeed
SetpointLimit (%)) is
built for hoist 2
Output from p22070
BOOL
(StartPulse_boEnable
BrakeStoreValue)
from hoist 2
Output from p22071
REAL
(StartPulse_rTorque
ValueRetain [%])
from hoist 2
BOOL
Output from p22072
(StartPulse_bo
CommandOpen
Brake) from hoist 2
BOOL
Output from p22073
(StartPulse_bo
CommandClose
Brake) from hoist 2
Output of r80[1] (CO:
REAL
Torque actual value,
Smoothed with
p0045) from hoist 2
Output of r1482 (CO:
REAL
Speed controller I
torque output) from
hoist 2
REAL
Output of r80[1] (CO:
Torque actual value,
Smoothed with
p0045) at previous
braking from hoist 2
REAL
Torque to be proven
for hoist 1, either the
value set in p22284
(H2_rMinimumTorque
(%)) or r22316
(H2_rOut_Actual
TorqueAtPrevious
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents