Fluid Circulation
Circulation Through Gun
Manifold
Do not circulate fluid containing a blowing agent with-
out consulting with your material supplier regarding
fluid temperature limits.
Circulating fluid through the gun manifold allows rapid
preheating of hose.
1. Install gun fluid manifold (P) on Part 246362 acces-
sory circulation kit (CK). Connect high pressure cir-
culation lines (R) to circulation manifold.
P
CK
2. Route circulation lines back to respective compo-
nent A or B supply drum. Use hoses rated at the
maximum working pressure of this equipment. See
Typical Installation, without circulation, page 10.
3. Follow Check Generator fuel level. Running out
of fuel will cause voltage fluctuations that can
damage electrical equipment., page 20.
4. Turn main power ON
5. Set temperature targets, see page 21. Turn on
A
B
,
, and
.
6. Press
to display actual temperatures.
28
R
ti2767a
.
heat zones by pressing
7. Circulate fluid at lowest possible pressure until tem-
peratures reach target.