4

Correct usage

When the air conditioner is used for the first time or when the setting is changed, follow the steps below.
Settings are saved in memory and are displayed anytime the unit is turned on by pushing the
Preparation
• When the circuit breaker is turned on, the partition lines are displayed on the remote controller.
* After the circuit breaker is turned on, the remote controller does not accept any commands for approx.
1 minute, this is not a failure.
REQUIREMENT
When the air conditioner is re-powered after it has not been used for a long period, turn on the circuit breaker at
least 12 hours before starting the air conditioner.
TEMP.
ON / OFF
4
TIMER SET
FAN
MODE
TIME
SAVE
VENT
FILTER
RESET
TEST
SET
CL
SWING/FIX
UNIT LOUVER
Start
1
Push
button.
The operation lamp illuminates, and the operation
starts.
2
Select an operation mode with the "
button.
One push of the button, and the display changes
in the order shown below.
Auto
Heat
Dry
Cool
Fan
77-EN
1117880601_EN.indd 40
1117880601_EN.indd 40
3
Select fan speed with "
" button.
One push of the button, and the display changes
in the order shown below.
Auto
High
Med
1
3
• When fan is in "
Auto", fan speed is
2
adjusted based on difference between set
point and room temperature.
• In heating operation, if the room temperature
is not heated sufficiently with speed "
operation, select "
Med." or "
operation.
• The temperature sensor detects the return air
temperature at the indoor unit, which differs
from the room temperature depending on the
installation condition.
Set point is a target of room temperature.
(
"Auto" is not selectable in the Fan
"
mode.)
4
Select the set point temperature by pushing
the "TEMP.
" or "TEMP.
" buttons.
Stop
Push
button.
The operation lamp goes off, and the operation stops.
NOTE
button.
Auto Changeover
• During Auto Mode, the unit selects the operating mode (cooling, heating or fan only) based on the user set point
temperature.
• If the Auto mode is uncomfortable, you can select the desired conditions manually.
Heating
• If there is a demand for heating, unit will start approximately 3 to 5 minutes after the mode is selected.
• After the heating operation has stopped, fan may continue to run for approx. 30 seconds.
• When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit fan runs at
extremely low speed.
• During defrost operation, the fan stops so that cool air is not discharged. (" " Pre-heat is displayed.)
When operation is restarted after stop
• When attempting to restart the unit immediately after it was stopped, the unit cannot start for approx. 3 minutes
this is to protect the compressor.
8°C operation (For object pre-heating)
The air conditioner can control the heating temperature to about 8°C in the heating mode.
Low
The 8°C heating operation requires settings with the wired remote controller. Ask the installer or dealer for
the settings according to the installation manual of the indoor unit.
Start
1. Set the displayed temperature to 18°C in the heating mode by pushing TEMP.
Low"
2. Set the displayed temperature to 8°C by pushing TEMP.
High"
Stop
1. Set the displayed temperature to 18°C by pushing TEMP.
• The air conditioner returns to the normal HEAT mode. Select a desired temperature and operation mode.
NOTE
• The discharged air temperature is lower than that in the normal heating operation.
• The room temperature may not be heated evenly depending on the remote controller installation location.
• The room temperature may not reach 8°C depending on the room size or the installation conditions.
• Setting for fan speed is available during the 8°C heating operation.
The 8°C heating operation is cancelled in the following cases.
• When operation is stopped with
• When another operation mode is selected with
• When temperature setting or operation mode is changed or operation is started / stopped by the wireless
remote controller or the central control remote controller.
• When this operation mode is used, observe proper operating hours and we recommend that you ask service
staff for periodic maintenance of the air conditioner.
– 40 –
button.
button for at least 4 seconds
button.
button
button