HOT TUB CONTROLS
MESSAGE BUTTONS
Message buttons provide reminders to help you keep your spa running smoothly. Message
buttons also provide warning information that helps spa technicians with troubleshooting.
When a message button appears (C), press it to view the
corresponding message (D) or (G). Press the Exit button (E)
to go back to the Main screen, or press the Clear button (F)
to dismiss the message.
Buttons vary depending on the type of message. View the
list below.

MESSAGES

General Messages
Several alerts and messages may be displayed in a sequence.
Possible freezing condition
A potential freeze condition has been detected, or the Aux Freeze Switch has closed. All water
devices are activated. In some cases, pumps may turn on and off and the heater may operate
during Freeze Protection. This is an operational message, not an error indication.
The water is too hot – M029*
The system has detected a spa water temp of 110°F (about 43°C) or more, and spa functions are
disabled. System will auto reset when the spa water temp is below 108°F (about 42°C). Check
for extended pump operation or high ambient temp.
The water level is too low
This message can only appear on a system that uses a water level sensor. It appears whenever
the water level get too low (or the water level sensor is disconnected), and automatically
disappears when the water level is adequate. Pumps and the heater turn OFF when this
message appears.