CHECKING FLOW
SETTING : After initialize Agilent 8960, Test GSM900, DCS,PCS mode
Set the property of audio as PRBS or continuous wave. Set the receiving volume of mobile as Max.
START
Does waveform at
TP1
fluctuate?
YES
Does waveform at
TP2
fluctuate?
YES
Check TP2 to make sure the
receiver connected
Properly?
YES
Receiver will work properly.
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
NO
Change the U103
NO
NO
Change the FPCB
NO
Resolder/Change the receiver