LG KP260 Service Manual page 113

Hide thumbs Also See for KP260:
Table of Contents

Advertisement

10. ENGINEERING MODE
10.5.3 Battery info
1) TEMP Cal : This displays the value of Temperature Calibration. The following menus are displayed
in order : TEMP_HIGH_LIMIT, TEMP_HIGH_RECHARGE_LMT, TEMP_LOW_RECHARGE_LMT,
TEMP_LOW_LIMIT
2) Bat Cal : This displays the value of Battery Calibration. The following menus are displayed in order :
BAT_LEV_4V, BAT_LEV_3_LIMIT, BAT_LEV_2_LIMIT, BAT_LEV_1_LIMIT, BAT_IDLE_LI MIT,
BAT_INCALL_LIMIT, SHUT_DOWN_VOLTAGE, BAT_RECHARGE_LMT
3) MVBAT ADC : This displays Battery voltage ADC.
4) AUX ADC : This displays AUX ADC.
5) TEMPER ADC : This displays temperature ADC.
10.5.4 Audio Tuning
Audio Tuning mode is designed to allow a engineer to view and tune the audio parameter.
1st Menu
1. Handset
2. Headset
3. Speakerphone
4. Bluetooth
LGE Internal Use Only
2nd Menu
3rd Menu
1 Uplink Gain
1. Analog Gain
2. Digital Gain
2 Downlink Gain
1. Analog Gain
2. Digital Gain
3 Sidetone Gain
0 ~ 100
4. Filter tables
1. default table
2. test table1
3. test table2
4. test table3
5. test table4
6. test table5
5. Echo Canceller
1. Uplink
2. Downlink
- 114 -
4th Menu
0 ~ 22.5 dB
0x0000 ~ 0xFFFF
12 ~ -48 dB
0x0000 ~ 0xFFFF
1. aecMode
1. Enable / 2. Disable
2. aecMicThreshold
0x0000 ~ 0xFFFF
3. aecResidualThreshold
0x0000 ~ 0xFFFF
4. aecMaxStepSize
0x0000 ~ 0x4000
5. aecEnableCoefUpdate
1. Enable / 2. Disable
6. aecEnableNlp
1. Enable / 2. Disable
7. aecNlpAttenuation
0x0000 ~ 0x7FFF
8. aecEnableComfortNoise
1. Enable / 2. Disable
9. aecDlUlDelay
0x0000 ~ 0xFFFF
10. aecMinLemCouplingFactor
0x0000 ~ 0x7FFF
11. aecMinLineCouplingFactor
0x0000 ~ 0xFFFF
12. aecTailControlGainTable
1. default table
2. test table 1
3. test table 2
4. test table 3
1. aecCtrl
1. Enable / 2. Disable
2. aecCnfg
0x0000 ~ 0xFFFF
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
5th Menu

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kp265

Table of Contents