Lincoln Electric IDEALARC DC-1500 Service Manual page 75

Constant voltage and constant current dc arc welding power source, 3 phase rectifier type
Hide thumbs Also See for IDEALARC DC-1500:
Table of Contents

Advertisement

F-41
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
TEST DESCRIPTION
The Active SCR Test will determine if the device is able to be gated "ON" and conduct cur-
rent from anode to cathode.
MATERIALS NEEDED
An SCR tester as outlined in this procedure.
DC-1500 Wiring Diagram (See Electrical Diagrams Section of this manual).
TROUBLESHOOTING AND REPAIR
ACTIVE SCR TEST PROCEDURE
WARNING
IDEALARC® DC-1500
F-41

Hide quick links: