Lincoln Electric INVERTEC 165S Operator's Manual
Hide thumbs Also See for INVERTEC 165S:

Advertisement

Quick Links

800036912
05/2019
REV02
INVERTEC 165S
OPERATOR'S MANUAL
ENGLISH
Lincoln Electric Bester Sp. z o.o.
ul. Jana III Sobieskiego 19A, 58-263 Bielawa, Poland
www.lincolnelectric.eu

Advertisement

Table of Contents
loading

Summary of Contents for Lincoln Electric INVERTEC 165S

  • Page 1 800036912 05/2019 REV02 INVERTEC 165S OPERATOR’S MANUAL ENGLISH Lincoln Electric Bester Sp. z o.o. ul. Jana III Sobieskiego 19A, 58-263 Bielawa, Poland www.lincolnelectric.eu...
  • Page 2: Table Of Contents

    12/05 THANKS! For having chosen the QUALITY of the Lincoln Electric products.  Please Examine Package and Equipment for Damage. Claims for material damaged in shipment must be notified immediately to the dealer.  For future reference record in the table below your equipment identification information. Model Name, Code &...
  • Page 3: Technical Specifications

    Technical Specifications PRIMARY SIDE Single phase supply 230 V Frequency 50/60 Hz Effective consumption 16 A Maximum consumption 34,4 A Fuse 16 A SECONDARY SIDE Open circuit voltage 85 V 5 A ÷ 160 A Welding current Duty cycle 20% 160 A Duty cycle 60% 100 A...
  • Page 4: Electromagnetic Compatibility (Emc)

    If any electromagnetic disturbances are detected the operator must put in place corrective actions to eliminate these disturbances with, if necessary, assistance from Lincoln Electric. This equipment does not comply with IEC 61000-3-12. If it is connected to a public low-voltage system, it is responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment may be connected.
  • Page 5: Safety

    Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
  • Page 6 SAFETY MARK: This equipment is suitable for supplying power for welding operations carried out in an environment with increased hazard of electric shock. CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used.
  • Page 7: Installation And Operator Instructions

    Installation and Operator Instructions LOW-VOLTAGE SUPPLY SYSTEM. THERE MAY BE Technical description POTENTIAL DIFFICULTIES ENSURING ELECTROMAGNETIC COMPATIBILITY IN THOSE Description LOCATIONS, DUE TO CONDUCTED AS WELL AS The system consists of a modern direct current RADIATED DISTURBANCES. generator for the welding of metals, developed via application of the inverter.
  • Page 8 Picture 1 Page 6.). Functions  Press the illuminated switch to turn on the power source (Ref. 1 - Picture 1 Page 6.). Front panel Picture 1 NOTE Serious damage to the equipment may result if the power source is switched off during welding operations. The power source is fitted with an anti-sticking device that disables power if output short circuiting occurs or if the electrode sticks, allowing it to be easily detached...
  • Page 9  Replace any illegible labels. time. Lincoln Electric is not in a position to warrant or  Clean and tighten the welding terminals. guarantee such advice, and assumes no liability, with ...
  • Page 10: Weee

    12/05 Part List reading instructions  Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service Department for any code number not listed.  Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine.