3. Disassembly and Reassembly

3-20 Replacing the Assy Valve Safety

WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range . Replace all panels before operating range . Failure to do so
can result in death or electrical shock .
WARNING
EXPLOSION, FIRE, AND ASPHYXIATION HAZARD
Shut off gas supply to the range before servicing . Check all gas lines and fittings for leaks before operating
the range . Replace all panels before operating range . Failure to do so can result in death or personal
injury from explosion, fire, or asphyxiation .
CAUTION
When you work on the gas range, be careful when handling sheet metal parts . Sharp edges may be
present, and you can cut yourself if you are not careful .
Parts
Assy Valve
Safety
This document can not be used without Samsung's authorization.
Explanation Photo
SUPPORT REGULATOR
[ Rear ]
ASSY VALVE SAFETY
[ Front ]
32
Explanation
1. Turn off the electrical supply going
to the range .
2. Shut off the gas shut-off valve in
the gas supply line to the range .
3. Remove the regulator support
bracket from the rear of the range
4. Carefully identify and mark the
wires going to the ASSY VALVE
SAFETY . Disconnect the 4 wires .
WARNING
Cross-wiring the wires to the
ASSY VALVE SAFETY creates an
explosion hazard that can result
in death, personal injury, and/or
property and product damage .
5. Using a tubing wrench and a
channel-lock wrench, disconnect
the 3 gas lines from the ASSY
VALVE SAFETY . Do not bend or
crimp gas lines during removal .
6. Remove gas fittings from the
ASSY VALVE SAFETY .
7. Remove 4 screws and the ASSY
VALVE SAFETY from the back wall
of the warming drawer opening .