RESTARTING AFTER THE ROLL OF FILM HAS RUN OUT
When the roll has finished, the display on the control
panel will read OUT OF FILM. Reload a new roll and
press the START button.
OPERATOR ASSISTANCE MESSAGES
In the instance of an error occurring, the following
messages may appear on the control panel:
01 Under Voltage
02 Over Voltage
EEPROM Error
REPLACING A DAMAGED BELT
1. Verify that power is off, machine is unplugged and
all components are cool.
2. Remove thumb screws on plastic belt cover.
(See Figure 3)
Figure 3
Thumb
Screws
3. Remove plastic belt cover. (See Figure 4)
Figure 4
PAGE 3 OF 15
OPERATING INSTRUCTIONS CONTINUED
03 Under Current
04 Over Current
Plastic Belt
Cover
Plastic
Belt
Cover
If an error message appears, please follow the
instructions below:
1.
Press the emergency stop button.
2. Leave for 30 seconds.
3. Retry the machine.
If this does not clear the error, hold Reset and Up Arrow
buttons simultaneously for 5 seconds. This will return the
machine to factory defaults. A minor adjustment to the
Heat Adjust parameter may be necessary to return to
ideal settings for the operator's environment.

MAINTENANCE

4. Use handle to lift heat seal mechanism. Slide
heating block towards drive wheel to release
tension on the belt. (See Figure 5)
Figure 5
Heat Seal Mechanism
5. While heat seal mechanism is elevated, remove the
belt. (See Figure 6)
Figure 6
Belt
6. Reverse steps 1 through 5 to replace belt.
Drive
Wheel
Handle
0415 IH-3518