Raffaello Megaline Espresso Coffee Machine
Raffaello Megaline
Espresso Coffee Machine
Technical Handbook and User Manual
Specifications subject to change without notice.
1

Advertisement

Table of Contents
loading

Summary of Contents for ECM Raffaello Megaline

  • Page 1 Raffaello Megaline Espresso Coffee Machine Raffaello Megaline Espresso Coffee Machine Technical Handbook and User Manual Specifications subject to change without notice.
  • Page 2 Raffaello Megaline Espresso Coffee Machine Contents Page Description General Data Introduction Important Safety Precautions Instruction for use Installation Electronic Control Board and Settings Main Features Hardware Function Programming of the keys System Programming Auditing Alarms and Time Outs Special functions...
  • Page 3 14 litres Dimensions: Raffaello Megaline A 1 and S 1 (W x D x height without feet): 475 mm x 515 mm x 500 mm / 18.7 in. x 20.3 in. x 19.7 in. Raffaello Megaline A 2 and S 2 (W x D x H without feet): 625 mm x 515 mm x 500 mm / 24.6 in.
  • Page 4 The instructions in this handbook are in no way a substitute for the safety instructions and technical data on the machine or the packaging concerning installation and function. The machines come with the following accessories: Raffaello Megaline A 1 and S 1: 1 Instruction manual 1 One cup filter holder...
  • Page 5 Raffaello Megaline Espresso Coffee Machine Important Safety Precautions Front view of machine (i.e.: Raffaello Megaline A 2) Fig. A • Read and understand all instructions. These instructions provide important information on the correct installation, safe and correct use and maintenance of this product. Thoroughly read this manual before you start to use this product.
  • Page 6 • Your machine should only be operated in accordance with instructions contained in this manual and verbal instructions and training provided by an authorised ECM dealer. • This machine is to be operated according to the instructions supplied in the handbook by a responsible and trained adult operator, authorized installation and/or service technician.
  • Page 7 Raffaello Megaline Espresso Coffee Machine • The machine should not be operated with temperatures under 8°C (46°F) and over 44 °C (110 °F). • The machine has to be used with soft clean drinking water: In case please use and adequate water filter.
  • Page 8 4°C or 39 °F and under 44 °C (110 °F). These operations have to be effected by an authorized service technician. • All maintenance must be carried out exclusively by ECM authorized service technicians. • All spare parts must be original parts.
  • Page 9 Raffaello Megaline Espresso Coffee Machine • Do not allow liquids to get inside the coffee machine. • Do not place heavy objects or climb on top of the coffee machine. • Do not use aerosol sprays near the machine. •...
  • Page 10 Raffaello Megaline Espresso Coffee Machine Installation This equipment is to be installed to comply with the applicable federal, state or local plumbing codes having jurisdiction. The manufacturer has tried to foresee all possible safety devices to ensure the safety of the users.
  • Page 11 Raffaello Megaline Espresso Coffee Machine 1. Electrical connection to the mains 2. Electric switch 3. Electric cable 4. Machine’s main switch (with Raffaello Megaline 2 groups) 5. Water inlet connection 6. Water discharge recipient 7. Water drain hose 8. Water hose to drain 9.
  • Page 12 Raffaello Megaline Espresso Coffee Machine Description of parts Fig. B Raffaello Megaline A 2 (2 group machine with automatic portion control) Steam handle Control light: “Machine on” Control light: “Boiler autofill” Touch panel Cups tray Steam wand (Caution: can become hot. Risk of injury!) Hot water wand (Caution: can become hot.
  • Page 13 Raffaello Megaline Espresso Coffee Machine Fig. C Raffaello Megaline A 1 (1 group machine with automatic portion control) Steam handle Control light: “Machine on” Control light: “Boiler autofill” Touch panel Cups tray Steam wand (Caution: can become hot. Risk of injury!) Hot water wand (Caution: can become hot.
  • Page 14 Programming product keys on Raffaello Megaline A 1 and Raffaello Megaline A 2 Raffaello Megaline espresso machines allow automatic portion control of coffee and hot water. Automatic portion control means that all coffee and hot water product keys (“buttons”) dispense a programmed quantity of coffee or hot water whenever you press them.
  • Page 15 Raffaello Megaline Espresso Coffee Machine Description of parts Fig. E Raffaello Megaline S 2 (2 group machine with semi-automatic portion control) Steam handle Control light: “Machine on” Control light: “Boiler autofill” Touch panel Cups tray Steam wand (Caution: can become hot. Risk of injury!) Hot water wand (Caution: can become hot.
  • Page 16 Raffaello Megaline Espresso Coffee Machine Fig. F Raffaello Megaline S 1 (1 group machine with semi-automatic portion control) Steam handle Control light: “Machine on” Control light: “Boiler autofill” Touch panel Cups tray Steam wand (Caution: can become hot. Risk of injury!) Hot water wand (Caution: can become hot.
  • Page 17 Raffaello Megaline Espresso Coffee Machine Fig. G Touch panel of Raffaello Megaline S1 and S2 Hot water key Semi-automatic portion control Semiautomatic portion control key: press to start coffee dispensing and press again to stop it. Hot water key: press to start hot water dispensing and press again to stop it.
  • Page 18 ECM authorized and qualified technician and is ready for use. Please proceed as follows: One group Raffaello Megaline machines (Raffaello Megaline A 1 and S 1) On/off switch on Raffaello Megaline A1 and S 1 Heater switch on Raffaello A 1 and S 1 Double pressare gauge.
  • Page 19 Raffaello Megaline Espresso Coffee Machine Two group Raffaello Megaline machines (Raffaello Megaline A2 and S2 This is the main switch on Raffello 2 group machines. Double pressare gauge. Shows boiler pressare and pump pressare 1. Turn main switch from position “0” (machine off) to position 1 (machine on but not heating up).
  • Page 20 Raffaello Megaline Espresso Coffee Machine Brewing ONE cup of coffee Automatic coffee portion Program and semi- control keys auto portion control Automatic hot water portion control key Hot water key Semi-automatic portion control Use one cup filter handle (with 1 spout) and the one cup filter basket.
  • Page 21 Raffaello Megaline Espresso Coffee Machine Brewing TWO cups of coffee Automatic coffee portion Program and semi- control keys auto portion control Automatic hot water portion control key Semi-automatic Hot water key portion control Use two cups filter handle (with 2 spouts) and the two cups filter basket.
  • Page 22 Push the hot water key on machine’s touch panel. With Raffaello Megaline A series machines you need just to push and the machine will stop dispensing once the preset quantity of hot water has been dispensed. With Raffaello Megaline S series machines (semi-automatic) you need to start AND top stop dispensing pushing both time the hot water key on the touchpanel.
  • Page 23 Raffaello Megaline Espresso Coffee Machine The manufacturer recommends the following operations: After every use: Clean the hot steam wand and spouts , as well as the hot water wand and end nozzle accurately with a clean non abrasive damp cloth after each single use without touching them directly with any part of the body to avoid injury or damage.
  • Page 24 Manufacturer: ECM s.p.a. Viale delle Industrie 26 20090 Settala (Milano) Italy This is to confirm that the Raffaello Megaline series of espresso machines has been manufactured according to the following standards: DIR. 89/336 • EN 55014-1 • EN 61000-3-2 (1995) •...
  • Page 25 Raffaello Megaline Espresso Coffee Machine Electric diagram Raffaello Megaline A 2 __________________________________________________________________________________ Specifications subject to change without notice.
  • Page 26 Raffaello Megaline Espresso Coffee Machine Raffaello Megaline A 2 electric diagram Main Switch (A) Pressure switch Thermo cut off switch Heating element Control board Pump Control lamp “machine on” Solenoid valve Group 1 Autofill control lamp Touchpanel Group 1 Probe for boiler water level control...
  • Page 27 Raffaello Megaline Espresso Coffee Machine Raffaello Megaline A 1 electric diagram Specifications subject to change without notice.
  • Page 28 Raffaello Megaline Espresso Coffee Machine Raffaello Megaline A 1 electric diagram Main Switch (A) Pressure switch Thermo cut off switch Heating element Control board Pump Control lamp “machine on” Solenoid valve Group 1 Autofill control lamp Touchpanel Group 1 Probe for boiler water level control...
  • Page 29 Raffaello Megaline Espresso Coffee Machine Raffaello Megaline S 2 electric diagram __________________________________________________________________________________ Specifications subject to change without notice.
  • Page 30 Raffaello Megaline Espresso Coffee Machine Raffaello Megaline S 2 electric diagram Main Switch (A) Pressure switch Thermo cut off switch Heating element Control board Pump Control lamp “machine on” Solenoid valve Group 1 Autofill control lamp Touchpanel Group 1 Probe for boiler water level control...
  • Page 31 Raffaello Megaline Espresso Coffee Machine Raffaello Megaline S 1 electric diagram __________________________________________________________________________________ Specifications subject to change without notice.
  • Page 32 Raffaello Megaline Espresso Coffee Machine Raffaello Megaline S 1 electric diagram Main Switch (A) Pressure switch Thermo cut off switch Heating element Control board Pump Control lamp “machine on” Solenoid valve Group 1 Autofill control lamp Touchpanel Group 1 Probe for boiler water level control...
  • Page 33 Raffaello Megaline Espresso Coffee Machine Different main switches and connections to the main switch Specifications subject to change without notice.
  • Page 34 Raffaello Megaline Espresso Coffee Machine Boiler and Hydraulics Specifications subject to change without notice.
  • Page 35 Raffaello Megaline Espresso Coffee Machine Pos. Code Description C277700505 Boiler 2 groups C277700504 Boiler 1 group C299900758 Pressure gauge C279900668 Pipe C229900674 Connector 1/4"x 1/8" C279900867 Right side steam wand C229900569 Plug 1/4" level control probe C199900295 Level control probe...
  • Page 36 Raffaello Megaline Espresso Coffee Machine Group Specifications subject to change without notice.
  • Page 37 Raffaello Megaline Espresso Coffee Machine Group Pos. Code Description 3way solenoid valve V. 208-220/60 C100001976 C449900786 Gasket OR 2025 Viton Gigleur cover TAGH C220001562 C449900232 Gasket gigleur 3/8" C619900554 Gigleur filter C200002805 Gigleur diam 1,2 TAGH Connector C229901064 C229900851 Left side group...
  • Page 38 Raffaello Megaline Espresso Coffee Machine Bodywork and Electrics Pos. Code Description Control box V 230/50-60 (from C100002807 200209…) C199900269 Flat cable L 800 mm C199900270 Flat cable L 1.000 mm C009900448 Cups support 2 group machine C639900456 Cups frame 2 group machine...
  • Page 39 Raffaello Megaline Espresso Coffee Machine Bodywork and Electrics Pos. Code Description C000301594 Side panel burgundy Side panel glossy black C000501594 C000201594 Side panel grey Side panel stainless steel C000701594 C000300452 Support burgundy Support glossy black C000500452 C000200452 Support grey C000700452...
  • Page 40 Raffaello Megaline Espresso Coffee Machine Bodywork and Electrics Pos. Code Description C199900949 Cord UL 1 cup spout C229900562 C229900566 2 cups spout 2 cup filter holder C699901066 C699901065 1 cup filter holder Filter holder C229900667 C619900098 Spring C000300453 Support burgundy...
  • Page 41 Raffaello Megaline Espresso Coffee Machine Raffaello Megaline A1 and S1 TAGH (temperature adjusting group head) Pos. Code Description C279901108 Pipe from solenoid valve to group C229900518 Connector 1/8" C100002793 Solenoid valve V 208-240/60 UL Pipe from solenoid valve to left side...
  • Page 42 Raffaello Megaline Espresso Coffee Machine Raffaello Megaline A2 and S2 TAGH (temperature adjusting group head) Pos. Code Description Pipe from solenoid valve to right side C200001681 flowmeter Connector 1/8" C229900518 C100002793 Solenoid valve V. 208-240/60 UL C279901108 Pipe from solenoid valve to group...
  • Page 43 Raffaello Megaline Espresso Coffee Machine Valve block Pos. Code Description C227700665 Valve block C019900101 Spring of retention valve C229900370 Retention valve C229900541 Expansion valve Spring of expansion valve C019900100 C229900595 L-Connector 1/4" Pipe from valve block to flowmeter ( 2 C279900875 gr.
  • Page 44 Raffaello Megaline Espresso Coffee Machine Pump Pos. Code Description C619900469 Pipe from pump to valve block C619900468 Pump connection pipe C229900523 Connector 3/8" C199900350 Pump C199900248 Motor W 100 V. 220/60 UL C449900753 Shock absorber Specifications subject to change without notice.
  • Page 45 Raffaello Megaline Espresso Coffee Machine Hot water valve Pos. Code Description C227700459 Hot water wand C319901079 Washer 1/4" stainless C329900682 Nut 1/4" C279900870 Pipe C229900520 Connector 1/4" C229900580 T-Connector 1/4" C100002808 Solenoid valve V 208-220/60 UL ODE C100002792 Solenoid valve V 208-240/60 Parker...
  • Page 46 Raffaello Megaline Espresso Coffee Machine Steam valve Pos. Code Description C439900800 Cover C439900371 Needle diam 2 mm C229900192 Washer C439900799 Handle C229900806 Valve C449900232 Gasket 3/8" C219901127 Spring H 22 C229900968 Support C449900191 OR gasket C277700907 Steam wand (brass) C200002024...