3. Maximum current ratings: Choose the pin 4-6 to configure the maximum output current ratings.
Table 7: Max Current Ratings
Configuration
000
O N
1
0
100
O N
1
0
010
O N
1
0
110
O N
1
0
Connect Input Wire
1. Install the copper wire as described. Insert the corresponding input wire into the terminal.
Copper wire type: 10 mm
Note:
Bottom-fed for indoor/outdoor installation, and rear fed for indoor installation.
Installation and Operation Manual
Max. Current Ratings
6A (Default)
8A
10A
12A
2
, 70ºC.
L1 L2
L3
Figure 11. Connecting the Input Wire
Installation and Operating Instructions
Configuration
001
O N
1
0
101
O N
1
0
011
O N
1
0
111
O N
1
0
N
PE
10
Max. Current Ratings
16A
20A
24A
32A