Service

Service
Service
Moving parts, such as an impeller blade, can cut
or amputate fingers. To reduce the risk of serious
injury, always shut off the agitator and disconnect
the air line before checking or repairing the agitator.
If the air motor requires more than installation of a
service kit, it is usually quickest and easiest to send it
to a Graco distributor for repair or replacement.
Motor rebuild kits are available and listed in the table
below. See manual 3A5050 for more information.
Kit
Kit
Kit
Description
Description
Description
25M535
Full air motor rebuild kit
25P720
Needle bearing rebuild kit
25P721
Single piston assembly rebuild kit
25P860
End cap kit
19Y509
Muffler kit (set of 3)
Removing the
the Air
Air Motor
Removing
Removing
the
Air
Models
Models
Models 25C528,
25C528, 25C529,
25C528,
25C529, 25C533,
25C529,
1. Follow the
Pressure Relief Procedure, page
2. Remove the air regulator by unscrewing the
swivel fitting (12).
• See
Model 25C528, page 25
• See
Model 25C529, page 28
• See
Model 25C533, page 26
• See
Model 25M481, page 27
3. Loosen the upper clamp (2) and raise the motor
so the upper two set screws (3) are accessible.
Use a 1/8 inch hex to remove the set screws
from the shaft.
4. Lift the air motor straight up off the shaft.
3A4792G
Motor
Motor
25C533, 25M481
25C533,
25M481
25M481
19.
Models 25C534,
25C534, 25C535
25C535
Models
Models
25C534,
25C535
1. Follow the
Pressure Relief Procedure, page
2. Remove the air regulator by
unscrewing the swivel fitting (11). See
Models 25C534, 25C535, page
3. Remove the screws (14) holding the motor
mounting plate (13) to the outlet housing (3).
4. Remove the socket head screws (2) holding the
motor (1) to the mounting plate.
5. Raise the motor so the two set screws (9) in the
shaft (4) are accessible. Use a 1/8 inch hex to
remove the set screws from the shaft.
6. Lift the air motor straight up off the shaft.
Model 25C530
Model
Model
25C530
25C530
1. Follow the
Pressure Relief Procedure, page
2. Remove the air regulator by unscrewing the
swivel fitting (9). See
3. Using a 3/16 inch hex, remove the three set
screws (8) on the bung adapter (4).
4. Raise the motor so the top two set screws (7) in
the coupler (3) are accessible. Use a 1/8 inch
hex to remove the top two set screws.
5. Lift the air motor (1) straight up off the coupler.
Models
Models 25N881,
Models
25N881, 25N882
25N881,
25N882
25N882
1. Follow the
Pressure Relief Procedure, page
2. Remove the air regulator by
unscrewing the swivel fitting (5). See
Models 25N881, 25N882, page
3. Remove the screws (11) holding the bung
adapter (6) to the motor plate (7).
4. Lift the motor off the bung adapter (6) and
remove the screws (8) that attach the motor plate
(7) to the motor (1).
Service
19.
29.
19.
Model 25C530, page
30.
19.
31.
23