Download Print this page

Service - Graco LSA 200 Instructions-Parts List Manual

Low shear agitators

Advertisement

WARNING
MOVING PARTS HAZARD
Moving parts, such as an impeller blade,
can pinch or amputate fingers. To
reduce risk of injury or damage to equip-
ment, always disconnect power from the agitator
before performing maintenance or service.
WARNING
HOT SURFACE HAZARD
During operation, the motor and the
shaft near the motor can get hot enough
to cause burns if touched. When working
with such equipment, wear appropriate protective
gloves and clothing. Allow the motor to cool for at
least one hour before touching either the motor or
the shaft.
WARNING
TOXIC FLUIDS HAZARD
Improper handling of hazardous fluids or
inhaling toxic fumes can cause ex-
tremely serious injury, even death, due
to splashing in the eyes, ingestion, or bodily con-
tamination. See Toxic Fluids Hazard on page 2.
Agitator and Shaft Removal
1. Make sure power is disconnected from the unit
(see Power Connection ).
2. Rotate the agitator shaft by hand until the drive
quill set screw is accessible through the access
hole in the housing. See Fig. 2, page 5.
3. Make sure the shaft is supported, then use a hex
key wrench to loosen the drive quill set screw two
turns to release the shaft.
4. Remove the shaft from the drive quill.

Service

5. Remove the agitator from the tank:
a. Make sure any lifting device used is of
adequate capacity for the agitator.
b. Loosen and remove the nuts and washers
securing the agitator to the mounting surface.
c. Lift and remove the agitator.
Lip Seal Removal and Replacement
The lip seal (71) and seal retainer plate (88) are lo-
cated at the bottom of the agitator flange. The lip seal
should be inspected periodically for wear or damage,
and replaced if necessary.
To inspect and replace the lip seal, with the agitator
removed from its mount, and the shaft removed (see
Agitator and Shaft Removal ):
1. Remove the flat head screws (87) holding the
retainer plate (88) in place. See Fig. 6.
2. Remove the retainer plate, and lip seal (71) from
the housing.
3. Inspect the seal for damage. Replace if neces-
sary.
4. To reinstall, place the new lip seal in flange (75),
and place retainer plate over the lip seal.
5. Secure the retainer plate and lip seal in place with
the flat head screws (87). Tighten securely.
Fig 6
RETAINER (88)
LIP SEAL (71)
310500