Overview Of Units; System Construction; Connectable Indoor Unit Lineup - Mitsubishi Electric PUMY-P250YBM Technical & Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for PUMY-P250YBM:
Table of Contents

Advertisement

2

OVERVIEW OF UNITS

2-1. SYSTEM CONSTRUCTION

Outdoor unit
Applicable
Capacity
indoor unit
Number of units
Total system capacity range
Model type
Model name
1-way cassette
PMFY-P·VBM-E
2-way cassette
PLFY-P · VLMD-E
4-way cassette
PLFY-EP · VEM-E *
PLFY-M · VEM-E
PLFY-P·VEM-E
PLFY-P·VEM-PA
2 by 2
PLFY-P·VFM-E1
Ceiling concealed PEFY-P·VMS1(L)-E
PEFY-P · VMA3-E *
PEFY-P·VMHS-E
PEFY-P·VMR-E-L/R
PEFY-M·VMA(2)(L)-A
PEFY-P·VMA(L)-E1
PEFY-P·VMA(L)-E3
PEFY-P·VMH-E/E2
PEFY-P · VMX(L)-E(1)
Ceiling suspended PCFY-P·VKM-E
Wall mounted
PKFY-P·VKM-E
PKFY-P·VLM-E
Ceiling concealed
PEFY-P·VMHS-E-F
(Fresh air type) *1
Floor standing
PFFY-P·VLEM-E
PFFY-P·VKM-E2
PFFY-P·VCM-E
Rossnay*5
GUF- · RD(H)4
Note: The lineup of a connectable indoor unit depends on a district/areas/country.
Remote
controller
*1 PUMY is connectable to Fresh Air type indoor unit. It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1
system) Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units. Refer
to "2-4-(3). Operating temperature range".
*2 When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual for the
CONNECTION KIT. Refer to the connectable indoor unit lineup in "2-2 SYSTEM CONSTRUCTION (BRANCH BOX SYSTEM)
for connectable indoor unit models.
*3 Authorized connectable indoor units are only as follows:
PUMY-P250 : PLFY-EP63VEM-E × 4
PUMY-P300 : PLFY-EP50VEM-E × 1 + PLFY-EP63VEM-E × 4
*4 Authorized connectable indoor units are only as follows:
PUMY-P250 : PEFY-P63VMA3-E × 4
PUMY-P300 : PEFY-P80VMA3-E × 1 + PEFY-P71VMA3-E × 3
*5 Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)
OCH760
10HP
P250YBM
50 to 130 % of outdoor unit capacity
(14.0 to 36.4 kW)
CMY-Y62-G-E
Branching pipe
components
Branch header
(2 branches)

Connectable indoor unit lineup

P10 P15 P20 P25 P32 P40 P50 P63 P71 P80 P100 P125 P140 P200 P250
3
4
Name
M-NET remote controller
Model number
PAR-F27MEA-E, PAR-U02MEDA
· A handy remote controller for use
in conjunction with the Melans
Functions
centralized management system.
· Addresses must be set.
Type 10 to Type 250
1 to 30 units
50 to 130 % of outdoor unit capacity
CMY-Y64-G-E
CMY-Y68-G-E
Branch header
Branch header
(4 branches)
(8 branches)
MA remote controller
PAR-4xMAA, PAR-3xMAA ("x"
represents 0 or later)
·Address setting is not necessary.
6
12HP
P300YBM
(16.8 to 43.5 kW)
CONNECTION KIT
PAC-LV11M-J
M series indoor unit
MSZ-EF Series
MSZ-FH Series
MSZ-LN Series
MFZ-KT Series
MSZ-AP Series
M series remote
controller
*2

Hide quick links: