Specifications - Mitsubishi Electric PUMY-P250YBM Technical & Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for PUMY-P250YBM:
Table of Contents

Advertisement

3

SPECIFICATIONS

3-1. OUTDOOR UNIT
Model
Power source
Cooling capacity
(Nominal)
Power input
Current input
EER
Temp. range of
Indoor temp.
cooling
Outdoor temp.
Heating capacity
(Nominal)
Power input
Current input
COP
Temp. range of
Indoor temp.
heating
Outdoor temp.
Indoor unit
Total capacity
connectable
CITY MULTI
Branch box
Branch box
1 unit
Branch box
2 units
Branch box
3 units
Sound pressure level (SPL) (measured in anechoic room) dB <A>
Power pressure level (PWL) (measured in anechoic room) dB <A>
Refrigerant
Liquid pipe
piping diameter
Gas pipe
FAN
Type × Quantity
Airflow rate
Control, Driving mechanism
Motor output
External static pressure
Compressor
Type × Quantity
Manufacturer
Starting method
Motor output
Case heater
Lubricant
External finish
External dimension HxWxD
Protection devices
High pressure protection
Inverter circuit (COMP./FAN)
Compressor
Fan motor
Refrigerant
Type × original charge
Control
Net weight
Heat exchanger
HIC circuit (HIC: Heat Inter-Changer)
Defrosting method
Standard attachment Document
Accessory
Optional parts
*1. Nominal cooling conditions (subject to ISO 15042)
Indoor: 27°CD.B./19°CW.B. [81°FD.B./66°FW.B.], Outdoor: 35°CD.B. [95°FD.B.], Pipe length: 7.5 m [24-9/16 ft.], Level difference: 0 m [0 ft.]
*2. Nominal heating conditions (subject to ISO 15042)
Indoor: 20°CD.B. [68°FD.B.], Outdoor: 7°CD.B./6°CW.B. [45°FD.B./43°FW.B.], Pipe length: 7.5 m [24-9/16 ft.], Level difference: 0 m [0 ft.]
*3. 10 to 52°C, when connecting following models: PKFY-P10/15/20/25/32VLM, PFFY-P20/25/32VKM, PFFY-P20/25/32VCM, PFFY-P20/25/32VLEM,
PEFY-P63/71/80VMA3-E; and M series type indoor unit.
*4. −15 to 52°C, when using an optional air protect guide [PAC-SK21AG-E]. However, this condition does not apply to the indoor unit listed in *3.
*5. Liquid pipe diameter: 12.7mm, when further piping length is longer than 90m, and when PEFY-P200 or P250 is connected.
*6. It is possble to set the External static pressure to 30 Pa by Dip Switch.
Notes:
・ Nominal conditions *1, *2 are subject to ISO15042
・ Due to continuing improvement, above specifications may be subject to change without notice.
OCH760
PUMY-P250YBM (-BS)
*1
kW
*1
kcal/h
*1
Btu/h
kW
A
kW/kW
W.B.
D.B.
*2
kW
*2
kcal/h
*2
Btu/h
kW
A
kW/kW
D.B.
W.B.
CITY MULTI
Branch box
Total (Quantity)
CITY MULTI
Branch box
kW type: P15-P50/ 10
Total (Quantity)
CITY MULTI
Branch box
kW type: P15-P50/ 12
Total (Quantity)
mm (inch)
mm (inch)
m³/min
L/s
cfm
kW
kW
kW
mm
inch
kg (lb) [-BS kg (lbs) ]
Grounded lead wire ×1
3-phase, 380-400-415V, 50Hz
28.0
24,100
95,500
8.21
13.35 - 12.68 - 12.22
3.41
15 to 24°C
−5 to 52°C
31.5
27,100
107,500
7.41
12.11 - 11.51 - 11.09
4.25
15 to 27°C
−20 to 15°C
50 to 130% of outdoor unit capacity
P10 - P250/ 30
kW type: P15 - P50/ 12
P10-P250/ 25
kW type: P15-P50/ 5
30
P10-P250/ 23
30
P10-P250/ 22
30
55 / 61
73 / 79
ø9.52 (3/8) *
5
ø22.4 (7/8)
Propeller Fan × 2
165/183
2750/3050
5826/6462
DC control
0.375 × 2
0Pa / 30Pa *
Scroll hermetic compressor × 1
Siam Compressor Industry Co., Ltd.
Inverter
5.7
-
FVC68D (3.0 litter)
Galvanized Steel Sheet
Munsell No. 3Y 7.8/1.1
1,662 × 1,050 × 460(+45)
65-7/16 × 41-11/32 × 187/64 (+ 1-49/64)
High pressure Switch
Overcurrent detection, Overheat detection (Heat sink thermistor)
Compressor thermistor, Overcurrent detection
Overheating, Voltage protection
R410A 9.3 kg
Linear Expansion Valve
196 (432) [198 (437)]
Cross Fin and Copper tube
Double pipe heat exchanger
Reversed refrigerant circuit
Installation Manual
Joint: CMY-Y62-G-E
Header: CMY-Y64/68-G-E
10
PUMY-P300YBM (-BS)
33.5
28,800
114,300
10.12
16.36 - 15.54 - 14.98
3.31
*3,*4
37.5
32,200
128,000
9.12
14.74 - 14.01 - 13.50
4.11
P10-P250/ 25
kW type: P15-P50/ 5
30
P10-P250/ 23
kW type: P15-P50/ 10
30
P10-P250/ 22
kW type: P15-P50/ 12
30
57 / 62
75 / 79
ø12.7 (1/2)
ø25.4 (1)
165/183
2750/3050
5826/6462
6
6.9
Joint pipe×1 set, Grounding lead wire ×1
Unit converter
kcal/h = kW × 860
Btu/h = kW × 3,412
cfm = m3/min × 35.31
lb = kg/0.4536
Above specification data
is subject to rounding
variation.