<Heating>
Figure 9 Indoor unit temperature correction
To be used to correct indoor unit capacity only
1.2
1.1
1.0
0.9
0.8
0.7
0.6
15
16
17
Figure 10 Outdoor unit temperature correction
To be used to correct outdoor unit capacity only
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
-20
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
-20
OCH760
18
19
20
21
22
23
24
Indoor Temperature [°C D.B.]
-15
-10
Outdoor Temperature [°C W.B.]
-15
-10
Outdoor Temperature [°C W.B.]
25
26
27
-5
0
-5
0
14
Indoor Temperature
5
10
15
Indoor Temperature
20°C D.B
15°C D.B
25°C D.B
5
10
15
20°C D.B.