Operation - Greenlee RK06AT Instruction Manual

Hydraulic crimping tool
Table of Contents

Advertisement

Operation

Electric shock hazard:
This tool is not insulated. When using
this unit on or near energized electri-
cal lines, use proper personal protec-
tive equipment.
Failure to observe this warning could
result in severe injury or death.
Wear eye protection when operating
this tool.
Failure to wear eye protection could
result in serious eye injury from flying
debris or hydraulic oil.
Skin injection hazard:
• Hand-tighten all couplers com-
pletely before operating the pump.
Do not use tools.
• Do not use hands to check for
leaks.
• Do not hold the hose or couplers
while the hydraulic system is
pressurized.
• Depressurize the hydraulic system
before servicing.
Oil under pressure easily punctures
skin causing serious injury, gan-
grene or death. If you are injured by
escaping oil, seek medical attention
immediately.
An incomplete crimp can cause a fire.
• Use proper connector and cable combinations.
Improper combinations can result in an incomplete
crimp.
• Crimp until the pump has reached relief pressure. If
you do not achieve relief pressure you will have an
incomplete crimp.
Failure to observe these warnings could result in
severe injury or death.
Greenlee Tools, Inc.
RK06AT Hydraulic Crimping Tool
Keep hands away from the crimping
tool head when crimping.
Failure to observe this warning could
result in severe injury or death.
Follow the instructions and safety information sup-
plied with the pump.
Failure to observe this warning could result in severe
injury or death.
1. Follow the lug manufacturer's instructions for appro-
priate cable strip length and surface prep aration.
2. Insert cable fully into connector. Center the con-
nector between the nibs.
Small connectors may become
RIGHT
wedged between the nibs of the tool.
Center the connector between the
four nibs before crimping.
Failure to observe this precaution
may cause property damage.
WRONG
CRIMPING DIRECTION
1ST COMPRESSION
SIDE A
CRIMPING DIRECTION
3. Using the sequence illustrated here, activate the
pump to advance the nibs. Continue crimping until
the pressure relief valve activates.
4. After achieving pressure relief, release the hydraulic
pressure at the pump. The ram will automatically
return to the start position and the nibs will retract.
5. Complete the number of crimps specified by the con-
nector manufacturer.
6
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
1ST COMPRESSION
CRIMPING DIRECTION
SIDE B
1ST COMPRESSION
SIDE B
SIDE A

Advertisement

Table of Contents
loading

Table of Contents