General Information; Technical Specifications - Theben Timeguard SupplyMaster FST24 Installation & Operating Instructions Manual

Fused spur time switch
Table of Contents

Advertisement

1. General Information

These instructions should be read carefully and retained for further
reference and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the
time switch is switched off and the circuit supply fuses are removed
or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used
for the installation of this time switch and install in accordance
with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this time
switch is fitted does not exceed the rating of the circuit cable,
fuse or circuit breaker.

3. Technical Specifications

• 230V AC 50 Hz
1
• Fused:
• Switch Rating:
• Contact Type:
• Minimum Depth of Wall Box: 25mm
• Boost Times:
• Power Status LED Indicator:
• Output LED Indicator:
• Operating Temperature:
• CE Approved
• Dimensions (H x W x D):
Note: Not suitable for use with Discharge Lighting.
Supplied with BS1362 13A Fuse
13A Resistive (3kW)
750W Incandescent,
Halogen lighting
500W Fluorescent lighting
200W LED lighting
100W Compact Fluorescent lighting
Normally Open
1, 2 hours
Red
Green
0°C to +40°C
85mm x 85mm x 31mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeguard supplymaster fst77

Table of Contents