IP65 Time Delay Switch
Press to Start
DS3HD
WARNING: Isolate from supply before
removing this cover

Advertisement

Table of Contents
loading

Summary of Contents for Theben Timeguard BoostMaster DS3HD

  • Page 1 IP65 Time Delay Switch Model: DS3HD - White IP65 Time Delay Switch Press to Start DS3HD WARNING: Isolate from supply before removing this cover...
  • Page 2 MAINS LIVE IN (right hand position of connector) SL - MAINS LIVE OUT (TO EXTERNAL LOAD) (second from right hand position of connector) EARTH – Connect any Earth wires to this pin N – NEUTRAL (IN) (fourth from right hand position of connector) N –...
  • Page 3 4. Internal Delay Selection Switches Four internal DIL switches are available to select 8 time delay settings as shown below. Please Note: On the DIL switch, switch 1 is not in use 2 mins 5 mins 10 mins 30 mins 60 mins 90 mins 120 mins 180 mins Time (minutes) Switch 4 Switch 3 Switch 2 180 Left = ON Right = OFF...
  • Page 4 Drain holes positions are shown below. The drain holes must be drilled out using a 5mm drill. Opening the drain hole will reduce the IP rating of the product. Four fixing holes Four drain holes Knock outs for cable conduit entry...
  • Page 5: Technical Specifications

    1. Technical Specifications Conforms to Directives: 73/23/EEC & 89/336/EEC Operating Voltage: 230V 50Hz Switching Capacity: Incandescent: 16A Fluorescent: 16A Resistive: 16A Motor: 1hp Operating temperature: -10°C to +40°C Timing range : 2 minute to 180 minutes in 8 steps Timing accuracy: +/- 2% Enclosure: Flame-resistant polycarbonate material. IP rating: IP 65 Dimensions: 94 mm x 94 mm x 57 mm Terminals: Suitable for 1.5mm...
  • Page 6 DS3HD IP65 Time Delay Switch Illuminated push button IP65 Time Delay Switch Press to Start DS3HD WARNING: Isolate from supply before removing this cover Figure 1 - Front Panel of DS3HD 1. General The DS3HD is a time delay switch designed to switch on an externally connected load to mains supply when the push button is pressed. It will then automatically switch off the load after a time...
  • Page 7: Functional Description

    2. Functional Description There is a single blue LED illuminated push button switch on the front panel. When pressed, the DS3HD will function as follows: • The blue LED will turn off. • An externally connected load will be switched on for the selected time delay. • One minute before the end of the time delay, the blue LED will flash. • At the end of the time delay, the externally connected load will be switched off from mains supply. • The blue LED will switch permanently on until the push button is pressed again. • If the push button is pressed when the time delay is still running, the delay will be terminated after 1 minute. • If the push button is pressed in the last minute of the time delay (when the blue light is flashing) the count down will be reset and the timer will...
  • Page 8: Mounting And Installation

    3. Mounting and Installation Warning: Switch off mains electricity before proceeding with installation. Four PCB mounting screws Four fixing Push holes button switch connector Mains supply input and output connector Time delay selector Four fixing holes Knock outs for cable glands Figure 2 - Internal of DS3HD IMPORTANT NOTICE: • This product should be installed in accordance...
  • Page 9 • Remove front panel by unscrewing the four fixing screws. • If necessary, carefully remove the printed circuit board (PCB) by undoing the four PCB mounting screws. • Remove knockouts at (preferably) the bottom of the box. • Use appropriate IP65 rated entry conduits to fit M20 knockouts. Ensure tight fitting for IP compliance. • Fix surface mount box rigidly to a secure surface by using appropriate screws through the four. fixing holes. • Refit the PCB back onto the surface mount box by progressively tightening each of the four PCB mounting screws in turn. Do not over tighten the screws • Ensuring that the mains wires are adequate for the required load cut the cable tails to the appropriate lengths. • Insert mains wiring through cable conduits. • Connect the mains wires to the mains connector as follows: Neutral Neutral in Earth...
  • Page 10 HELPLINE 020 8450 0515 or email helpline @ timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Offi ce: 020 8452 1112 or email csc @ timeguard.com Designed in the U.K. 67-058-381...

Table of Contents