Download Print this page
Theben TR 644 S Operating Instructions Manual

Theben TR 644 S Operating Instructions Manual

Time switch programming with software obelisk

Advertisement

Quick Links

TR 641 S
Ref. Nr. 641 0 001
TR 641 S DCF
Ref. Nr. 641 0 301
Bedienungsanleitung
Mit Software Obelisk programmierbar
Mode d'emploi
Programmation avec logiciel Obelisk
Operating instructions
Time switch programming with
software Obelisk
Istruzioni d'uso
Programmazione con software Obelisk
Gebruiksaanwijzing
Programmering met software Obelisk
1
31
59
87
115
TR 644 S
TR 644 S DCF TR 608 top TR 610 top
TR 611 top
TR 622 top TR 030 top

Advertisement

loading

Summary of Contents for Theben TR 644 S

  • Page 1 Operating instructions Time switch programming with software Obelisk Istruzioni d’uso Programmazione con software Obelisk Gebruiksaanwijzing Programmering met software Obelisk TR 644 S TR 644 S DCF TR 608 top TR 610 top TR 611 top TR 622 top TR 030 top...
  • Page 2 1.0 Description of the Product 2.0 Features 1 Display DCF 77 reception (only TR 641 S DCF) – 1-Channel-Yearly Time Switch 2 Display data exchange with Obelisk – Time switch programming or PC programming using WIN 95 / WIN 98 / WIN NT 3 Display hours with Obelisk software 4 Interface...
  • Page 3 Description (page 59) Programming (page 72) 7.1 Programming weekly program (page 72) Features (page 59) 7.2 Programming data program (page 73) Application / Installation (page 61) 7.3 Programming single switching times (page 73) 3.1 Safety instructions (page 61) 7.4 Programming pulse program (page 74) 3.2 Installation instructions (page 61)
  • Page 4: Application Installation

    We therefore recommend attention be given to the following points before 3.0 Application / installation installation: Time switches switch ON, OFF and over connected electrical units, depending on – Use separate lead for the mains voltage supply. time, on a daily or weekly cycle and related to date. –...
  • Page 5 Note 3.4 Technical data The time switches conform to the European Regulations 73/23/EWG (low volta- ge rules) and 89/336/EWG (EMV-Regulations). Description: Yearly Time Switch If the time switches are used with other products in one installation, attention Program Type: Day/Week must be given to ensure that the whole installation does not cause radio interfe- Supply Voltage: 230 V~ ±...
  • Page 6 4.0 Power reserve 4.2 Battery changing Important Instructions In the event of a power failure, the battery back-up provides for the maintenace Battery changing with mains voltage of correct time (approx. 1.5 years). Even without power and with a drained bat- All memorised program data is maintained tery, the switching times remain permanently stored.
  • Page 7 Ending Programming: use v button, and place cursor ▲ into following 5.0 Initial operation position Ensure that the lithium battery is located (Chapter 4.1) 5.1 Overview of menu selection 5.2 Entry adjustment By pressing the button v ▲ can be moved. the Cursor The TR 641 S / TR 641 S DCF contains a prompt facility.
  • Page 8 Note: 5.3 Setting date and time After the initial operation (Chapter 5.3) automatic Summer/Winter time is already On initial operation press button RES with a pointed object e.g. pencil, and after- programmed. wards release it. Basic setting is for Central Europe: dat 1. Initial operation of the Radio controlled Time switch TR 641S DCF see chapter 5.7.
  • Page 9 5.5 Changing automatic summer/ winter time 5.6 Changing date / time Default: TR 641 S: dat 1 With the cursor in Pos. n, any flashing value, the actual time or date, can be changed with the buttons 0 .. 9. Default: TR 641 S DCF: dat 0 Select the new switching time (Chapter 5.4)
  • Page 10 5.7 Radio Time Switch TR 641 S - TR 641 S DCF The operation of the radio time switch is exactly the same as with the TR 641S. A. Operation without DCF 77 radio reception The correct time, date and Summer-/Wintertime change-over set themselves In this case, set the summer-/ winter change to the correct changeover standard, automatically with me DCF 77 radio receiver.
  • Page 11 5.9 Initial Operation of the Radio Time Switch A. Setting-Up Automatically Note: During synchronisation press no buttons! The synchronisation test would be discontinued immediately. To obtain a new start after this, RES button must be pressed again. TR 641S DCF 1.
  • Page 12 Example: The time switch has synchronised itself on 19.5.2000 at 9.25. 6.0 Manual intervention in the program 6.1 Automatic operation (standard setting) Res. The channel C take in the switching condition provided the stored time program. Auto 6.2 Permanent ON 5.10 Forced Transmitter Call The channel C can be manually switched in each menu to permanently ON.
  • Page 13 6.4 Manual ON (override switching) 6.6 Random program The channel C can be switched ON manually in the automatic program. In which General Comment case, the symbol H = hand appears in the display. A random program causes the time switch to switch ON or OFF at random bet- An override switching is cancelled again by the next switching command.
  • Page 14 6.7 Random program start 6.9 Locking/ unlocking the keyboard Effect: A random program can be switched ON manually in the automatic program (Auto) at any time. It remains active until switched OFF (chapter 6.8). Obelisk memory card allows you to prevent operation of the device by unaut- horized persons.
  • Page 15 Example 2: Weekly program – set switch OFF time 7.0 Programming – Channel C is to switch OFF at 18.30 from Mon to Fri p 7.1 Weekly program, set switch ON time e.g.: Channel C is to switch on at 6.30 from Mon to Fri o Place cursor ▲...
  • Page 16 7.2 Programming date program 7.3 Programming single switching time Example: Channel C, 1 switches ON on the 10.5 at 8.30 Example.: Channel C is to switches ON on the 1.5 at 7.30 Place cursor ▲ in pos. Note: Only date related switching times can be programmed with the fun- ction 1x see illustration 8.
  • Page 17 7.4 Programming pulse program 8.0 Priority program With the TR 641 S / TR 641 S DCF up to 9 different weekly programs can be Example: Channel C pulse duration: 5 secs from Mon to Fri at 7.15. Place cursor ▲ in pos. performed in addition to the normal weekly program.
  • Page 18 Overview TR 641 S – TR 641 S DCF Weekly program schedule with priority weekly program weekly program Date „standard“ weekly program P8 Permanently Priority times switching weekly program P7 ON/OFF P1-P9 times weekly program P6 weekly program weekly program P5 „Priority 1“...
  • Page 19 8.2 Setting Time Period for Weekly Program P1 .. P9 8.1 Programming weekly program with priority P1 .. P9 A. Recurring annually Example Channel C switches on daily at 8.15 Priority sequence P1. The time period of a weekly program P1 .. P9 is fixed by entering a commence- ment and finishing date.
  • Page 20 B. Weekly program only in one specified year C. Stipulating public holidays without a fixed date Example: Only in year 2000 from 8th April to 27th May, e.g. the weekly Example: Following this measure, a public holiday such as Easter 2000 program P2 activated.
  • Page 21 8.3 Time limited permanent switching ON or OFF 9.0 Programe interrogation E.g.: All connected equipment is to remain switched OFF during the Christmas 9.1 Whole program interrogation holidays between 23 December 1999 and the 7 January 2000. Menu Selection cursor under ? By pressing ENTER button (several times) interrogate whole program.
  • Page 22 9.5 Interrogating weekly program with priority 9.3 Interrogation of date program Illustration 1: Menu selection and display of the free memory locations e.g. 304 Fig. 1: Display of available memory space 304 Fig. 2: Select: Channel C1 Illustration 2: Select date program, press button Dat twice Fig.
  • Page 23 10.0 Changing a stored program Any program already stored, whether weekly or yearly can be changed depending on individual requirements. Condition: Cursor must be in the interrogation menu (?). Select Confirm Example: Illustration 1: example: free memory locations 304 Illustration 2: By repeatedly pressing the Enter Button, call up the switching time to be changed Illustration 3:...
  • Page 24 11.0 Cancellation 11.2 Cancellation of Dat program 11.1 Cancellation of individual switching times Illustration 1: Menu selection ? and display of free memory locations e.g. 304 Illustration 2: Select date switching times, press button Dat twice. Illustration 1: Menu selection ? and display of free memory locations e.g. 304. Illustration 3: Begin interrogation from January: press Button 0, 1 (February 0, 2 etc.) Illustration 4: Search for the switching time to be cancelled, press Enter Button.
  • Page 25 11.3 Cancellation of the whole priority program 11.4 Cancel everything Illustration 1: Menu selection ? and display of free memory locations e.g. 304 Illustration 1: Menu selection ? and display of free memory locations e.g. 304 Illustration 2: Initiate the cancellation procedure, press CL Button Illustration 2: Cancel program, press Button CL Illustration 3: Select channel e.g.
  • Page 26 12.0 Data Exchange / Security Switching times of time switch TR 641 S / TR 641 S DCF can be stored externally with the Obelisk memory card.The data can be filed or transferred from time switch to time switch. Illustration 4 12.3 Preview Programming with Obelisk Software Order No.
  • Page 27 Note: After a time adjustment, only pulses, which are programmed at 13.0 Tips and additional possibilities least 1 minute after the time adjustment, are carried out. 1. Priority program with random switching 4. Pulse program for time delayed switch-OFF Possibility for starting a random program automatically during public or A switch-OFF time e.g.
  • Page 28 What does Obelisk memory card mean? 14.0 Glossary Mobile data carrier can be used for: What does automatic operation (Auto) mean? – security of the programmed time program The cursor is below Auto. Current time is displayed. – duplication of the programmed time program The switching sequence of the time switch is determined by the stored swit- –...
  • Page 29 15.0 Table of errors In order to increase the reliability of operation, several internal tests are run by the time switch. If any error appears during these tests, the LCD will display the following error numbers. Error no. 4, 5, 6, 7: Error in the transmittance of data memorized in the memory card Obelisk.
  • Page 30 TEMPOLEC International s.a., Route de Biesme 49, 6530 Thuin, Fax. 02 08/4 52 51 43 Tél. 071.59.00.39 (10 lignes), Fax. 071.59.01.61 THEBEN S.R.L., via Ciro Menotti 11, 20129 Milano THEBEN (Schweiz) AG, Schwettistraße 152, 5704 Egliswil, Tel. 02/7 38 61 41/2/3/4, Fax. 02/7 38 61 44 Tel.

This manual is also suitable for:

Tr 644 s dcfTr 608 topTr 610 topTr 611 topTr 622 topTr 030 top