1... DESCRIPTION
CN
2... GENERAL ADVICE
3... INSTALLATION
CZ
4... RUNNING THE HEATER
DE
5... MAINTENANCE
6... TRANSPORTING AND MOVING YOUR HEATER
DK
7... TROUBLESHOOTING
EE
IMPORTANT!!! Carefully read this service manual before
ES
Improper use of the appliance may cause serious injuries,
FI
FR
►►1. DESCRIPTION
BV MODEL space heaters have been de-
GB
signed for use in small to medium-sized
rooms and buildings where a fi xed or mo-
GR
bile heating system is required. Heat is
HR
produced by combustion and the heat from
the smoke is transmitted to the fresh air
HU
through the metal walls of the combustion
chamber and the heat exchanger. The
IT
combustion chamber is of the type where
LT
smoke circulates twice. The air and smo-
ke pass through separated ducts, both
LV
of which are welded and sealed. When,
after combustion, the waste gases have
NL
cooled, they are expelled through a duct
NO
which must be connected to a chimney or
chimney fl ue. The chimney or chimney fl
PL
ue must be big enough to guarantee that
the smoke is expelled effi ciently. The air
PT
which is used in combustion is aspirated
RO
directly from the room or building which
is being heated. It is therefore of utmost
RU
importance that the room or building be
properly ventilated so that enough fresh
SE
air is circulating at all times.
SI
CONTROL BOARD (fig. 1)
1. Control lamp
SK
2. Control knob ON/OFF/vented only
3. Power cord
TR
4. Limit therm. with manual restart
UA
5. Burner plug
6. Burner fuse holder
YU
PARAGRAPH SUMMARY
you start to use, repair or clean the heater.
burns, electric shock or fire.
7. Cable fastener for room thermostat
8. Overheattherm. control lamp
9. Fan stop control lamp
DEVICE SCHEMATICS (fig. 3)
1. Casing
2. Blast chamber
3. Ventilator
4. Burner
5. Air outlet
6. Chimney connection
7. Air intake
8. Heat exchanger
9. Engine
►►2. GENERAL ADVICE
WARNING! Heater should be
connected with a good earthand
via a differential switch.
These heaters run with oil burners. Follow
all local ordinances and codes when using
this heater.
► Make sure that this owner's manual is
read and understood before trying to ope-
rate and service this heater.
► Use only in places free of fl ammable
materials.
► Have fi re fi ghting equipment available.
► Use only in well vented areas and have
a fresh air supply adapted to the heater
requirements.
► Locate heater permanently on a stable

Advertisement