Ieee Standards - Dell EMC PowerSwitch Z9432F-ON Installation Manual

Hide thumbs Also See for EMC PowerSwitch Z9432F-ON:
Table of Contents

Advertisement

Table 6. Environmental parameters (continued)
Parameter
Maximum operational altitude
Maximum nonoperational altitude
Shock
Acoustic
NOTE:
Acoustic numbers indicate a potential high-to-
low range. Volume may increase as power demands and
environmental temperature rise.
1
NOTE:
The idle condition was defined idle load with
OS running and no optics port population and operating
condition was defined the 100% traffic with full optics
(x32) population.
2
NOTE:
The LwA,m is declared A-weighted Sound Power
Level per ISO9296 (2017) with data collected from single
sample and the statistical adder is 0.4 bels.
3
NOTE:
The LpA,m is the A-weighted sound pressure
level at the bystander position per section 4.3 of ISO 9296
(2017) and measured in accordance to ISO 7779 (2010).
The system is placed on ISO table.
4
NOTE:
Prominent tones: Criteria of D.6 and D.11 of
ECMA-74 (17th ed., Dec. 2019) are followed to determine
if discrete tones are prominent and to report them.
NOTE:
Redundant AC power requires high-line 200 VAC to 240 VAC. Using low-line 120 VAC does not provide redundancy
for the switch.
Table 7. AC power requirements
Parameter
Power supply
Maximum current draw per system
Maximum power consumption (28x15W and 4x20W QSFP56-
DD optics)
Typical power consumption
Table 8. DC power requirements
Parameter
Minimum and maximum input voltage range
Maximum current at full load with fan

IEEE standards

The Z9332F-ON switch complies with the following IEEE standards.
● 802.1ab (LLDP)
● 802.1ax (Layer 2)
48
Specifications
Specifications
3,048 meters (10,000 ft)
10,668 meters (35,000 ft)
Dell EMC Spec SV0115 (108000336_REV_25)
I/O-to-PSU (front-to-back) fan direction:
1
● 25C idle
@ 30% duty cycle, 6.9 bels
1
● 25C operating
@ 60% duty cycle, 7.8 bels, 66 dBA
● 35C operating @ 70% duty cycle, 8.5 bels
● 45C operating @ 100% duty cycle, 9.3 bels, 80 dBA
NOTE:
There is prominent tone at 270 Hz /234 Hz under
25C idle/operating condition, respectively.
PSU-to-I/O (back-to-front) fan direction:
● 25C idle @ 30% duty cycle, 6.9 bels, 60 dBA
● 25C operating @ 70% duty cycle, 8.4 bels, 73 dBA
● 35C operating @ 80% duty cycle, 8.7 bels
● 45C operating @ 100% duty cycle, 9.1 bels, 82 dBA
NOTE:
No prominent tone under 25C idle/operating
4
condition.
Specifications
● 90–130 VAC (110 VAC nominal)
● 180–264 VAC (240 VAC nominal)
● 12.0/10.0 A at 100/120 VAC (one PSU operating)
● 6.8/5.7 A at 200/240 VAC (two PSUs operating)
● Low Line VAC: 1200 W (one PSU operating)
● Low Line VAC: 1362 W (two PSUs operating)
● High Line VAC: 1362 W
900 W
Specifications
−40, –48V, –60V DC
−40V/24.0A −48V/20.25A −60V/16.2A
2
3
, 58 dBA
4

Advertisement