Endress+Hauser Proline 500 Brief Operating Instructions
Endress+Hauser Proline 500 Brief Operating Instructions

Endress+Hauser Proline 500 Brief Operating Instructions

Digital foundation fieldbus transmitter with coriolis sensor

Advertisement

Quick Links

KA01233D/06/EN/01.16
71310820
Products
Brief Operating Instructions
Proline 500 – digital
FOUNDATION Fieldbus
Transmitter with
Coriolis sensor
These instructions are Brief Operating Instructions; they are
not a substitute for the Operating Instructions pertaining to
the device.
Transmitter Brief Operating Instructions
Contain information about the transmitter.
Sensor Brief Operating Instructions →  3
Solutions
Services

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Proline 500

  • Page 1 Products Solutions Services KA01233D/06/EN/01.16 71310820 Brief Operating Instructions Proline 500 – digital FOUNDATION Fieldbus Transmitter with Coriolis sensor These instructions are Brief Operating Instructions; they are not a substitute for the Operating Instructions pertaining to the device. Transmitter Brief Operating Instructions Contain information about the transmitter.
  • Page 2 Proline 500 – digital FOUNDATION Fieldbus Order code: XXXXX-XXXXXX Ser. no.: XXXXXXXXXXXX Ext. ord. cd.: XXX.XXXX.XX Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555 Endress+Hauser...
  • Page 3 Proline 500 – digital FOUNDATION Fieldbus Brief Operating Instructions for the device Brief Operating Instructions for the device The device consists of a transmitter and a sensor. The process of commissioning these two components is described in two separate manuals: •...
  • Page 4: Table Of Contents

    Table of contents Proline 500 – digital FOUNDATION Fieldbus Table of contents Document information ............5 Symbols used .
  • Page 5: Document Information

    Proline 500 – digital FOUNDATION Fieldbus Document information Document information Symbols used 1.1.1 Safety symbols Symbol Meaning DANGER! DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING! This symbol alerts you to a dangerous situation.
  • Page 6 Document information Proline 500 – digital FOUNDATION Fieldbus Symbol Meaning Protective ground connection A terminal which must be connected to ground prior to establishing any other connections. Equipotential connection A connection that has to be connected to the plant grounding system: This may be a potential equalization line or a star grounding system depending on national or company codes of practice.
  • Page 7: Basic Safety Instructions

    Proline 500 – digital FOUNDATION Fieldbus Basic safety instructions Basic safety instructions Requirements for the personnel The personnel must fulfill the following requirements for its tasks: ‣ Trained, qualified specialists must have a relevant qualification for this specific function and task.
  • Page 8: Workplace Safety

    Verification for borderline cases: ‣ For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability as minute changes in the temperature, concentration or level of contamination in the process can alter the corrosion resistance properties.
  • Page 9: Security

    Proline 500 – digital FOUNDATION Fieldbus Basic safety instructions IT security We only provide a warranty if the device is installed and used as described in the Operating Instructions. The device is equipped with security mechanisms to protect it against any inadvertent changes to the device settings.
  • Page 10: Product Description

    Product description Proline 500 – digital FOUNDATION Fieldbus Product description The measuring system consists of a Proline 500 - digital transmitter and a Proline Promass or Cubemass Coriolis sensor. The transmitter and sensor are mounted in physically separate locations. They are interconnected by a connecting cable.
  • Page 11: Installation

    Proline 500 – digital FOUNDATION Fieldbus Installation Installation For detailed information about mounting the sensor, see the Sensor Brief Operating Instructions →  3 CAUTION Ambient temperature too high! Danger of electronics overheating and housing deformation. ‣ Do not exceed the permitted maximum ambient temperature .
  • Page 12: Wall Mounting

    Installation Proline 500 – digital FOUNDATION Fieldbus Wall mounting 17 (0.67) 5.8 (0.23) 5.8 (0.23) 149 (5.85) A0029054  2 Engineering unit mm (in) Depends on order code for "Transmitter housing" Order code for "Transmitter housing" • Option A, aluminum coated: L =14 mm (0.55 in) •...
  • Page 13: Electrical Connection

    Proline 500 – digital FOUNDATION Fieldbus Electrical connection Electrical connection NOTICE The measuring device does not have an internal circuit breaker. ‣ For this reason, assign the measuring device a switch or power-circuit breaker so that the power supply line can be easily disconnected from the mains.
  • Page 14 Electrical connection Proline 500 – digital FOUNDATION Fieldbus Signal cable FOUNDATION Fieldbus Twisted, shielded two-wire cable. For further information on planning and installing FOUNDATION Fieldbus networks see: • Operating Instructions for "FOUNDATION Fieldbus Overview" (BA00013S) • FOUNDATION Fieldbus Guideline • IEC 61158-2 (MBP) Current output 0/4 to 20 mA Standard installation cable is sufficient.
  • Page 15 Proline 500 – digital FOUNDATION Fieldbus Electrical connection 5.1.3 Connecting cable Non-hazardous area, Ex Zone 2, Class I, Division 2 Standard cable A standard cable can be used as the connecting cable. Standard cable 4 cores (2 pairs); pair-stranded with common shield Shielding Tin-plated copper-braid, optical cover ≥...
  • Page 16 Electrical connection Proline 500 – digital FOUNDATION Fieldbus Cross-section Cable length Termination 2 x 2 x 0.50 mm 50 m (165 ft) (AWG 22) • +, – = 0.5 mm • A, B = 0.5 mm 3 x 2 x 0.50 mm...
  • Page 17 Proline 500 – digital FOUNDATION Fieldbus Electrical connection Transmitter and sensor connection housing: connecting cable The sensor and transmitter, which are mounted in separate locations, are interconnected by a connecting cable. The cable is connected via the sensor connection housing and the transmitter housing.
  • Page 18: Connecting The Measuring Device

    Electrical connection Proline 500 – digital FOUNDATION Fieldbus Connecting the measuring device NOTICE Limitation of electrical safety due to incorrect connection! ‣ Have electrical connection work carried out by correspondingly trained specialists only. ‣ Observe applicable federal/national installation codes and regulations.
  • Page 19 Proline 500 – digital FOUNDATION Fieldbus Electrical connection Connecting the connecting cable to the sensor connection housing Connection via terminals with order code for "Housing" Available for sensor Option A "Aluminum, coated" →  20 • Promass A, E, F, H, I, O, P, Q, S •...
  • Page 20 Electrical connection Proline 500 – digital FOUNDATION Fieldbus Connecting the sensor connection housing via terminals 10 (0.4) 3 mm TX 20 TX 20 22 mm 24 mm A0029616 Loosen the securing clamp of the housing cover. Unscrew the housing cover.
  • Page 21 Proline 500 – digital FOUNDATION Fieldbus Electrical connection Connecting the sensor connection housing via terminals 10 (0.4) 8 mm 22 mm 24 mm A0029613 Release the securing screw of the housing cover. Open the housing cover. Push the cable through the cable entry . To ensure tight sealing, do not remove the sealing ring from the cable entry.
  • Page 22 Electrical connection Proline 500 – digital FOUNDATION Fieldbus Connecting the sensor connection housing via the connector A0029615 Connect the protective ground. Connect the connector. Endress+Hauser...
  • Page 23 Proline 500 – digital FOUNDATION Fieldbus Electrical connection Connecting the connecting cable to the transmitter TX 20 TX 20 10 (0.4) 22 mm 24 mm A0029597 Loosen the 4 fixing screws on the housing cover. Open the housing cover. Fold open the terminal cover.
  • Page 24 Electrical connection Proline 500 – digital FOUNDATION Fieldbus 5.2.2 Connecting the signal cable and the supply voltage cable A0028200 Cable entry for supply voltage Cable entry for cable or connection of device plug for signal transmission Cable entry for cable or connection of device plug for signal transmission...
  • Page 25 Proline 500 – digital FOUNDATION Fieldbus Electrical connection Strip the cable and cable ends. In the case of stranded cables, fit ferrules. Connect the protective ground. Connect the cable in accordance with the terminal assignment .  Signal cable terminal assignment: The device-specific terminal assignment is documented on an adhesive label in the terminal cover.
  • Page 26: Ensuring Potential Equalization

    Electrical connection Proline 500 – digital FOUNDATION Fieldbus Ensuring potential equalization 5.3.1 Requirements No special measures for potential equalization are required. For devices intended for use in hazardous locations, please observe the guidelines in the Ex documentation (XA). Ensuring the degree of protection The measuring device fulfills all the requirements for the IP66/67 degree of protection, Type 4X enclosure.
  • Page 27: Operation Options

    Proline 500 – digital FOUNDATION Fieldbus Operation options Operation options Overview of operation options A0029295 Local operation via display module Computer with Web browser (e.g. Internet Explorer) or with operating tool (e.g. FieldCare, DeviceCare, AMS Device Manager, SIMATIC PDM) Field Xpert SFX350 or SFX370...
  • Page 28: Structure And Function Of The Operating Menu

    Operation options Proline 500 – digital FOUNDATION Fieldbus Structure and function of the operating menu 6.2.1 Structure of the operating menu Operating menu for operators and maintenances Language Operation task-oriented Setup Diagnostics Operating menu for experts Expert function-oriented A0014058-EN  3 Schematic structure of the operating menu 6.2.2...
  • Page 29: Access To The Operating Menu Via The Local Display

    Proline 500 – digital FOUNDATION Fieldbus Operation options Access to the operating menu via the local display X X X X X X 19.184 mA 12.5 X X X X X X Language à English 20.50 Deutsch Español Français User...
  • Page 30 Operation options Proline 500 – digital FOUNDATION Fieldbus 6.3.1 Operational display Explanatory symbols for the measured value Status area • Depends on the device version, e.g.: The following symbols appear in the status area of the – : Volume flow operational display at the top right: –...
  • Page 31 Proline 500 – digital FOUNDATION Fieldbus Operation options Numeric editor Confirms selection. Moves the input position one position to the left. Exits the input without applying the changes. Inserts decimal separator at the input position. Inserts minus sign at the input position.
  • Page 32: Access To The Operating Menu Via The Operating Tool

    Operation options Proline 500 – digital FOUNDATION Fieldbus Keys and meaning Reduces the contrast (brighter setting). Plus/Enter key combination (press and hold down the keys simultaneously) Increases the contrast (darker setting). Minus/Plus/Enter key combination (press the keys simultaneously) For operational display:Enables or disables the keypad lock.
  • Page 33: System Integration

    Proline 500 – digital FOUNDATION Fieldbus System integration System integration For detailed information on system integration, see the Operating Instructions for the device. Overview of device description files – Current version data for the device – Operating tools Cyclic data transmission Cyclic data transmission when using the device master file (GSD).
  • Page 34 System integration Proline 500 – digital FOUNDATION Fieldbus Display text (xxxx... = serial number) Base index Description PID_ xxxxxxxxxxx 5800 PID function block (PID) INTEGRATOR_xxxxxxxxxxx 6000 Integrator function block (INTG) 7.1.2 Description of the modules The input value of a module/function block is defined via the CHANNEL parameter.
  • Page 35 Proline 500 – digital FOUNDATION Fieldbus System integration CHANNEL Measured variable HBSI Current input 1 Visible depending on the order options or device settings MAO module (Multiple Analog Output) Channel Description Channel_0 Structure Channel_0 Value 1 Value 2 Value 3...
  • Page 36 System integration Proline 500 – digital FOUNDATION Fieldbus CHANNEL Device function State Empty pipe detection 0 = off, 1 = active Verification status Overall result of the verification Verification: • 16 = Failed • 32 = Passed • 64 = Not performed...
  • Page 37 Proline 500 – digital FOUNDATION Fieldbus System integration Value Device function State Value 1 Reset totalizer 1 0 = off, 1 = execute Value 2 Reset totalizer 2 0 = off, 1 = execute Value 3 Reset totalizer 3 0 = off, 1 = execute...
  • Page 38 System integration Proline 500 – digital FOUNDATION Fieldbus 7.1.3 Methods Method Block Navigation Description Set to "AUTO" Resource Block Via menu: This method sets the Resource Block mode Expert → Communication → Resource and all the Transducer Blocks to the block →...
  • Page 39: Commissioning

    Proline 500 – digital FOUNDATION Fieldbus Commissioning Commissioning Function check Before commissioning the measuring device: ‣ Make sure that the post-installation and post-connection checks have been performed. • "Post-installation check" checklist →  12 • "Post-connection check" checklist →  26...
  • Page 40: Configuring The Measuring Device

    Diagnostic information Proline 500 – digital FOUNDATION Fieldbus Configuring the measuring device The Setup menu with its submenus and guided wizards is used for fast commissioning of the device. They contain all the parameters required for configuration, such as for measurement or communication.
  • Page 41 Proline 500 – digital FOUNDATION Fieldbus Diagnostic information X X X X X X X X X X X X X X 20.50 S801 Supply voltage Menu Diagnostic list Diagnostics 1 S801 Supply voltage Diagnostics 2 Diagnostics 3 Supply voltage...
  • Page 44 www.addresses.endress.com...

Table of Contents