Panasonic DLP PT-RZ34K Operating Instructions Manual page 292

Table of Contents

Advertisement

Class
Command
Input terminal name
2
INNM ?
query
Input signal resolution
2
IRES ?
query
Recommended
2
RRES ?
resolution query
FREZ
Freeze control
2
FREZ ?
Freeze status query
Cooling notification
2
POWR
Warmup notification
2
ERST
Error notification
2
LKUP
Link up notification
Input switch
2
INPT
completion notification
2
SRCH
Projector search
PJLink security authentication
A PJLink password for security authentication procedure is required for communication of the PJLink command.
The PJLink password can be set in the [NETWORK] menu → [PJLink] → [PJLink PASSWORD] (x page 221), or
in "[Set up password] page (when accessed by administrator account)" (x page 256) of the web control screen.
When communicating the PJLink command without authentication procedure, set the PJLink password as blank.
The factory default setting of the PJLink password is blank.
f For specifications related to PJLink, visit the website of Japan Business Machine and Information System
Industries Association.
URL http://pjlink.jbmia.or.jp/english/
292 - ENGLISH
Chapter 7 Appendix — Technical information
Parameter/response
Control details
string
31 / HDMI
32 / DVI-D
33 / SDI
34 / DIGITAL LINK
35 / SLOT-1
36 / SLOT-2
37 / SLOT-3
38 / SLOT-4
AAAAxBBBB
1920x1200
0
1
0
1
xxxxxx
xx:xx:xx:xx:xx:xx
31
32
33
34
35
36
37
38
ACKN=xx:xx:xx:xx:xx:xx
Remark
SLOT-1 (name of the input 1 of the Interface Board installed in
<SLOT>)
SLOT-2 (name of the input 2 of the Interface Board installed in
<SLOT>)
SLOT-3 (name of the input 3 of the Interface Board installed in
<SLOT>)
SLOT-4 (name of the input 4 of the Interface Board installed in
<SLOT>)
AAAA: Horizontal resolution
BBBB: Vertical resolution
Returns display resolution.
Freeze clear
Freeze (stop)
Notifies when the power is turned off.
Notifies when the power is turned on.
Notifies when an error occurs.
Notifies the MAC address when the PJLink communication
becomes possible.
HDMI
DVI-D
SDI
DIGITAL LINK
SLOT-1 (input 1 of the Interface Board installed in <SLOT>)
SLOT-2 (input 2 of the Interface Board installed in <SLOT>)
SLOT-3 (input 3 of the Interface Board installed in <SLOT>)
SLOT-4 (input 4 of the Interface Board installed in <SLOT>)
The projector connected to the same network that can
communicate with PJLink will respond with its MAC address.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dlp pt-rz34kdDlp pt-rz34ke

Table of Contents