Configuring Communication

Configuring Communication
Communication between the NXP-PLV and a Master Controller is done using either USB or
ETHERNET (DHCP or Static IP). Ethernet communication can be achieved through a direct
connection.
Before commencing, verify you are using the latest NetLinx Master and device
firmware. Also, verify you are using the latest versions of AMX's NetLinx Studio and
TPDesign4 programs. The firmware and applications are available at
www.amx.com.
USB input devices must be plugged into the rear USB connector before the device is
powered up. The device will not detect a USB connection of this type until after the
unit cycles power.

Panel Setup

1. From the Camera Options or Camera Limits touchscreen pages, touch the Panel Setup button to
open the Setup page (FIG. 32).
FIG. 32
Setup page
2. Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected
Setup page and display an on-screen keypad.
3. Enter the default password 1988 into the keypad's password field and press Done when finished.
Clearing Password #5 from the initial Password Setup page removes the need for
you to enter the default password before accessing the Protected Setup page.
27
Connection Status
Red
Connection Status icon -
indicates no connection
to a Master
Green
Connection Status icon -
indicates communication
to a Master
NXP-PLV Modero PosiTrack Pilot Camera Controller