Replace Fuses In Harness (25R652); Recycling And Disposal; End Of Product Life - Graco Therm-O-Flow 200 Instructions - Parts Manual

Warm melt
Hide thumbs Also See for Therm-O-Flow 200:
Table of Contents

Advertisement

Repair
Replace Fuses in Harness
(25R652)
The harness comes with fuses installed. Follow these
steps to replace a fuse.
1. Turn the Disconnect Switch (T) OFF.
2. Remove the Heat Control Box door (452).
3. Unscrew the spring-loaded fuse holder to open it.
The fuse can be easily removed by hand.
Open Here
F
. 54
IG
4. Install the new fuse.
5. Reconnect and tighten the fuse holder.
6. Install the Heat Control Box Door (452).
To prevent damage to the AMZ circuit board, use
only 5 x 20 mm, 10 Amp AC, fast acting fuses. Fast
acting fuses are required for short-circuit protection.
116
NOTICE

Recycling and Disposal

End of Product Life

At the end of the product's useful life, dismantle and
recycle it in a responsible manner.
Perform the Pressure Relief Procedure.
Drain and dispose of fluids according to applicable
regulations. Refer to the material manufacturer's
Safety Data Sheet.
Remove motors, batteries, circuit boards, LCDs
(liquid crystal displays), and other electronic
components. Recycle according to applicable
regulations.
Do not dispose of batteries or electronic
components with household or commercial waste.
Deliver remaining product to a recycling facility.