Mitsubishi Electric MELSENSOR VS20 Connection Manual page 19

Vision sensor, fa sensor
Hide thumbs Also See for MELSENSOR VS20:
Table of Contents

Advertisement

Outputting to the programmable controller
1.
Set data to be output from the vision sensor to the programmable controller.
As an example, set PASS, FAIL, and the number of inspection to the output word block (D1015 to D1017).
2.
Select the data to be output to the programmable controller.
3.
Display the output result to the programmable controller.
 Device Address: D1015 to D1017
 Message size (words): 3
 Items corresponding to the device address can be changed by using the [Up] and [Down]. As an example, sort as above for easy viewing.
 Click [Add].
 Select "Pattern_1 inspection result
(PASS/FAIL)".
 Select "Job.Inspection_Count".
 Click [OK].
1 THE SLMP SCANNER CONNECTION
1.3 Vision Sensor Setting