5.3 Ventilation

Ensure that there is an air exchange rate of at least 1.5 times per hour, and at least
3
3,885 ft
(110 m
This machine generates a slight amount of ozone during normal use. Although
sensitivity to ozone may vary, this amount is not harmful. Ozone may be more
noticeable during extended use or long production runs, especially in poorly
ventilated rooms. It is recommended that the room be appropriately ventilated,
sufficient to maintain a comfortable working environment, in areas of machine
operation.

5.4 Elevation Limitations

Install this machine at an elevation below 13,123' (4,000 m) and at an air pressure
of less than 607.8 hPa.

5.5 Lighting

We recommend installing the machine in a location with at least 500 lux
(29 1/2" (75 cm) above the floor) for normal operation and maintenance.

5.6 Sunlight

Avoid installing the machine in direct sunlight. If this is unavoidable, use curtains to
shade the machine. Be sure that the curtains do not block the machine's ventilation
slots or louvers, or interfere with the electrical cord or power supply.

5.7 Ammonia

Avoid installing the machine where ammonia is emitted. In a sufficient amount,
ammonia will attack the surfaces of the machine's paper feed and image quality
components, thereby shortening their useful life and increasing the need for
periodic and remedial maintenance.
A professional assessment of the air quality in the room in which the machine is to
be installed is recommended prior to its installation.
Version 5
3
) of space in the location where the machine will be installed.
imagePRESS C6000 Customer Expectations Document