OPERATION
POWER WAVE 300C
®
MEMORY OPERATION
FIGURE B.19
Memories can be saved for each welding process. These can be accessed by touching the applicable
memory bu�on labeled one through four.
To save a memory, hold the desired memory loca�on down un�l the screen indicates the memory is
saved.
When one memory is selected the LED will be lit, if any se�ngs are changed the LED will go out. If the
memory bu�on is pressed again, the se�ngs will revert to the se�ngs saved in the memory.
Four dis�nct memories can be saved for each process to the 4 memory bu�ons on the User Interface.
4 for SMAW, 4 for GTAW, 4 for GMAW, and 4 for FCAW. There are also 6 addi�onal memory slots
available for each process within the Memories Menu, allowing for a total of 40 possible memories.
All memories can be reviewed on the memory �le screens. These �les can be accessed via the
"Memories" op�on of the System Menu or by pressing any 2 memory bu�ons simultaneously.
B-23