Siemens SITRANS LVL200S Operating Instructions Manual page 13

Dpdt relay
Hide thumbs Also See for SITRANS LVL200S:
Table of Contents

Advertisement

Transport
Pressure/Vacuum
Handling
SITRANS LVL200S l RELAY (DPDT)
You can give your SITRANS LVL200S additional protection
against moisture penetration by leading the connection cable
downward in front of the cable entry. Rain and condensation
water can thus drain off. This applies mainly to mounting
outdoors, in areas where moisture is expected (e.g. by
cleaning processes) or on cooled or heated vessels.
Fig. 6: Measures against moisture penetration
Do not hold SITRANS LVL200S on the tuning fork. Particularly
with flange or tube versions, the tuning fork can be damaged
just by the weight of the instrument. Transport coated
instruments very carefully and avoid touching the tuning fork.
Remove the protective cover just before mounting.
The process fitting must be sealed if there is gauge or low
pressure in the vessel. Before use, check if the seal material is
resistant against the measured product and the process
temperature.
The max. permissible pressure is specified in chapter
"Technical data" or on the type label of the sensor.
The vibrating level switch is a measuring instrument and must
be treated accordingly. Bending the vibrating element will
destroy the instrument.
Warning:
The housing must not be used to screw the instrument in!
Applying tightening force can damage internal parts of the
housing.
Use the hexagon above the thread for screwing in.
Mounting
13