Checking And Adjustment During Board Replacement; Preparation - Sony IPELA XIS-10DC Service Manual

Wide view camera
Hide thumbs Also See for IPELA XIS-10DC:
Table of Contents

Advertisement

Checking and Adjustment During Board Replacement

n
The PTZ camera (SNC-RZ30NB) of the unit is the equiva-
lent of the network camera SNC-RZ30N.
For adjustment of the PTZ camera, refer to the service
manual of SNC-RZ30N.

4-1. Preparation

4-1-1. Service Tool List
. Personal computer
CPU:
Pentium III 500 MHz or more
RAM capacity:
128 MB or more
PC monitor:
XGA or higher enabling display
OS:
Widows 98, 2000, Me, XP,
Windows NT4.0
Web browser:
Internet Explorer 5.5/6
Browser setting:
Java can be used
Security level:
Middle or less
Proxy:
OFF
Others:
Anti-virus and stopped all fire walls
. LAN cable (cross cable)
n
When using a straight cable, connect the unit to the PC
through a HUB that is not connected to any other
networks.
. Power supply for this unit
n
Refer to Section 1-7 and prepare a power supply unit that
meets the required performance specification.
. Memory Stick (16 MB or more)
. PC card adaptor (MSAC-PC3)
XIS-10DC
Section 4
4-1-2. Connection
m
. Connect after the louver and the upper case assembly
have been removed.
(Refer to steps 1 to 3 in Section 2-2.)
. Reattach the louver and the upper case assembly after
completing all checks and adjustments.
PC
LAN cable
CN6
SNT-1 board
PC card slot
SNT-1 board
S153
CN6
D162(NETWORK)
D163(POWER)
D161(NETWORK)
CN12
S151
4-1 (E)