Dukane iQ Auto-Plus 20AT060-U Series User Manual page 36

Ultrasonic generator/power supply
Table of Contents

Advertisement

iQ Series,
Auto-Plus User's Manual
Options for U/S Activation Connections:
Optionally monitor the U/S Active status output on
I/O connector Pin 4.
This status output signal will activate when
U/S is ON.
Optionally monitor the Ready status output on sys-
tem I/O connector Pin 4.
This status output signal will activate when the
system, including the MPC module is ready.
4.
Other options the operator can check:
Fault Status output signals
Fault Status output signals are available for Overload
(Pin 3) or Any Fault (Pin 5).
These status outputs will activate when a fault
occurs:
An Overload Fault latches until the next time
U/S is activated.
Any Fault status activates when any fault is de-
tected by the system. The output will latch until
U/S is activated unless the fault is Overtempera-
ture or Power Not OK.
Five fault conditions are monitored by the iQ Auto-
Plus system for Any Fault:
Average Overload
(Automatically resets on next cycle)
Peak Overload
(Resets same as Average Overload)
Overtemperature
(Automatically resets on cool-down)
Power Not OK
(AC line voltage under minimum voltage)
Frequency Overload
(Automatically resets on next cycle)
Over Voltage Overload
(Automatically resets on next cycle)
Page 30
Continued from Previous Page
5. Check MPC Channels
Check that all MPC channels can be selected and
activated. The automation control system activates
input selection bits.
Select a channel:
indicator illuminates GREEN when it is the selected
channel.
Activate ultrasound: Activate the iQ Auto-Plus ul-
trasound output on I/O connector Pin 12. The
SELECTION STATUS
nel should switch to RED (from GREEN).
The probe on the selected channel should deliver
ultrasonic power.
Repeat this test for all MPC channels.
PROBE SELECTION STATUS
indicator on the selected chan-
Dukane Manual Part No. 403-591-01
PROBE