Dometic 8 Series Operating Manual page 29

Absorber refrigerator
Hide thumbs Also See for 8 Series:
Table of Contents

Advertisement

Available languages

Available languages

Operation with batteries (internal power supply)
Indicator
flashing
3
brightly
8
flashing
3
brightly l
7
Acoustic signal at 15
second intervals
Automatic
switching
from external to internal
power supply does not
function
(absence of the on-
board 12 V power sup-
ply for the electronics)
Fault
Flame not ignited
Burner defective or coo-
ling unit defective
Undervoltage detection
(internal batteries)
Refrigerator does not
function;
gas operation not possi-
ble although the batte-
ries are inserted.
Remedy
Check gas supply (gas bottle, gas valve)
Press the
button after clearing the fault.
Check burner, burner nozzles, if necessary contact
Customer Service and arrange replacement
Replace batteries
Switch off the refrigerator and start again.
The on-board power supply was interrupted during
the starting of the gas operation.
Note: No automatic switching is performed during
the ignition.
27