Power Supply; Transistor Output; Self Diagnostic Functions; Operating Environment - Omron H7CR-A Series Manual

Compact 1/16 din counters, four- or six-digit lcd displays
Table of Contents

Advertisement

H7CR

POWER SUPPLY

When the power turns OFF then ON, the input signal may or
may not be received. The diagram below shows when the input
signal will be received, will not be received or will be unstable.
The unstable period will vary with power supply voltage, and
the load conditions on external power supplies.
Power
On
supply
Off
0 to 50 ms
Input
Not
received

TRANSISTOR OUTPUT

The transistor output in H7CR counters is optically isolated
from the internal circuitry by a photocoupler, so either NPN or
PNP output is possible.

SELF DIAGNOSTIC FUNCTIONS

The displays at right appear when irregularities occur. When
the problems causing these conditions have been cleared, the
preset count value and all outputs will be reset in the same way
as when the Reset key is pressed.

OPERATING ENVIRONMENT

Although the front of the counter resists water and oils and can
be used where subject to these, extended exposure to large
amounts of either can adversely affect internal components.
The counter, input signal lines, and the input device must be
separated as far as possible from any sources of electrical
OTHER
Always isolate the counter from external circuits or short all
terminals before measuring dielectric strength between electric
circuits and non-charged metal parts or performing similar
testing with the counter mounted in a control panel. This is to
prevent internal circuit damage that might occur if the test
voltage enters the counter interior due to withstand-voltage or
insulation failure in control panel devices.
10 ms
0 to 0.9 s
Not
Received
received
Unstable
For 100 to 240 VAC and 24 VAC/12 to 24 VDC counters, be
sure that the capacity of the external power supply is adequate,
because the power supply may not provide a surge current
sufficient to start the counter due to the switching regulator
contained in the counter's internal circuitry.
Connect the power supply voltage through a relay or switch in
such a way that the voltage reaches a fixed value immediately.
Display
Meaning
– – – –
Present value
below minimum
FFFFFF Present value
above maximum
E1
CPU error
E2
Memory error
– – – –:
Displayed for +/– range counters H7CR-C and H7CR-SC when
max. negative value is exceeded.
FFFFFF:
Displayed for +/– range counters H7CR-C and H7CR-SC when
max. positive value is exceeded.
noise, such as high-voltage power lines. Shielded input signal
lines can also be effective in suppressing noise.
To prevent damage, the exterior of the counter must not be
exposed to organic solvents (e.g., paint thinner or benzene),
strong alkalis, or strong acids.
The counter contains a lithium battery, and must never be
incinerated. Dispose of the counter as a noncombustible item.
26
H7CR
Outputs Recovery
Not
Press RESET key
changed. for 1 second or
reset input.
OFF
Press RESET key
for 1 second.