9.2.4

Antenna

9.2.5

Conduit entries

½–14 NPT
9.2.6

Enclosure ratings (702)

NEMA
9.2.7

Mounting

Transmitters may be attached directly to switch, brackets also permit remote mounting.
See
Dimensional drawings
9.3

Performance specifications

9.3.1

Electromagnetic compatibility (EMC)

Meets all industrial environment requirements of EN61326 and NAMUR NE-21. Maximum
deviation <1% span during EMC disturbance.
(2) During surge event device may exceed maximum EMC deviation limit or reset; however, device will self-recover and return to normal
operation within specified start-up time.
Reference Manual
CMN: Common
CH2+: Channel two positive
CMN: Common
COMM: Communication terminals
PBT/PC integrated omnidirectional antenna
®
4X and IP66/67
for more information.
Appendix B specifications and reference data
(2)