Anchor Types
Anchor
HSL
HST
• HS Anchors listed are Metric Hilti™ Concrete Anchors
• Minimum concrete compressive strength: 3000psi (20 N/mm2)
• Minimum concrete thickness:
• HSL-3 M 8: 4-3/4" (120mm)
• HST M12 : 5-1/2" (140mm)
• Minimum distance from anchor to concrete edge or seam:
• HSL-3 M 8: 2-3/8" (60mm)
• HST M12: 4-3/4" (120mm)
• Minimum hole depth in concrete:
• HSL-3 M 8: 3-1/64" (80mm)
• HST M12 Safety Stud Anchor (EMEA): 3.7" (95mm)
• Minimum concrete embedment:
• HSL-3 M 8: 2-13/32" (60mm)
• HST M12 Safety Stud Anchor (EMEA): 2.8" (70mm)
Anchor Specifications
Static Anchor
HSL-3 M8/40
HST M 12
Pullout Force
Life Fitness specifies Hilti
design pullout force (in tension) for the specified anchors, when properly installed in cracked concrete, is provided in
the side table. This table should be used for reference only; for additional and up-to-date information on the anchor
capabilities or the design pullout force in other substrates, please consult Hilti directly at https://www.us.hilti.com.
Subfloor thickness between unit and concrete
0" - 3/4" (0mm - 19.1mm)
HSL-3 M 8/40
Minimum Concrete
Minimum Drill Depth
Thickness
4-3/4" (120mm)
5-1/2" (140mm)
™
static and dynamic anchors. According to the anchor manufacturer, the recommended
3/4" - 1.0" (19.1mm -
25.4mm)
HST M12 x 115/20 to HST M12 x 295/200
(length depends on subfloor thickness)
Minimum Concrete
in Concrete
1/2" (12.7mm)
2-13/32" (60mm)
beyond anchor
length
25/64" (10mm)
beyond anchor
length
Page 45 of 48
1.0" - 7.0" (25.4mm -
178mm)
Minimum concrete
Embedment
compressive strength
3000psi (20.7 N/
2.8" (70mm)
3000psi (20.7 N/
mm2)