6.1 Power up troubleshooting

Problems at power up and their possible causes and solutions are described here.
Product does not turn on or keeps turning off
Possible causes
Blown fuse / tripped breaker 1.
Poor / damaged / insecure
power supply cable /
connections
Incorrect power connection
Power source insufficient
Product will not boot up (re-boot loop)
Possible causes
Power supply and
connection
Software corruption

6.2 AIS data troubleshooting

No AIS targets shown on the display
Possible causes
Data / network problem
VHF antenna fault
GNSS (GPS) antenna fault
AIS feature not enabled on
display
44
Possible solutions
Check the condition of fitted fuses and breakers and
connections, replace if necessary.
2. Ensure fitted fuse rating is correct (3 A)
3. If fuse keeps blowing check for cable damage, broken connector
pins or incorrect wiring.
1.
Check that the power cable connector is fully inserted into the
product and locked in position.
2. Check the power supply cable and connectors for signs of
damage or corrosion, replace if necessary.
3. With the product powered on, try flexing the power cable near
to the product connector to see if this causes the product to
re-boot/loose power, replace if necessary.
4. Check the product's power supply voltage, the condition of the
battery terminals and power supply cables, ensuring connections
are secure, clean and free from corrosion, replace if necessary.
5. With the product powered on and where applicable, transmitting,
using a multi-meter, check for a voltage drop across all
connectors /fuses etc, and replace if necessary.
The power supply may be wired incorrectly, ensure the installation
instructions have been followed.
Check that your power supply (battery or distribution panel) is
providing a minimum of 10.2 V to the product.
Possible solutions
See possible solutions from 'Products does not turn on or keeps
turning off' above.
In the unlikely event that the product's software has become
corrupted, please try re-flashing the product with the latest software
from the Raymarine website:
Possible solutions
Review and carry out solutions in the
data
table below.
Check the VHF antenna is properly connected and is not short
circuiting to the vessel structure.
Check the GNSS (GPS) antenna is properly connected and is
installed in an appropriate location (e.g.: clear view of the sky).
Refer to the Operation instructions for your display to identify how
to enable the AIS feature.
www.raymarine.com/software